- Page 7 of 10 -
Report
No.
123035
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
Bibliogra
phy in
EN
60065:20
02
phy in
EN
60065:20
02
Replace the paragraph related to prEN 50332-2 by:
EN 50332-2:2003, Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Matching of
sets with headphones if either or both are offered separately EN
60065:2002/A1:2006 - 4 -
EN 50332-2:2003, Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Matching of
sets with headphones if either or both are offered separately EN
60065:2002/A1:2006 - 4 -
N/A
Bibliogra
phy in IEC
60065:200
1/A1:2005
phy in IEC
60065:200
1/A1:2005
Add the following notes for the standards indicated:
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994
(not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991
(not modified).
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994
(not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991
(not modified).
N/A
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Class II apparatus
N/A
13.3.1
NO: To the second paragraph the following is
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
Noted
P