CS-VE9NKE, CS-VE12NKE, CU-VE9NKE, CU-VE12NKE - Panasonic Air Conditioner Service Manual (repair manual). Page 116

Read Panasonic CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE Service Manual online

116 
16.2.8.3  Process 2 (Removing Brazing Point) 
1  Removing butyl tape from piping prior to removing the brazing point. 
 
 
 
Caution 
Protection from the brazing flame should be considered during replacing the parts. 
Firstly disconnect the pipe which entering to heat charger, discharging from heat charger, compressor 
suction and the discharging pipes. 
 
 
16.2.8.4  Separate Compressor from Heat Charger. 
1  Take out blocks of compressor and heat charger from the base pan. 
2  Cut off 2 bands (top and bottom) which holding compressor and heat charger, and lift the bracket to remove. 
3  Remove the heat transferring sheet from the compressor once separate the heat charger from compressor. 
4  Remove the sensor on heat charger by peeling off polyethylene sheet. Keep the sensor for re-use after the 
brazing work. 
 
 
Page of 127
Display

Click on the first or last page to see other CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE service manuals if exist.