CS-VE9NKE, CS-VE12NKE, CU-VE9NKE, CU-VE12NKE - Panasonic Air Conditioner Service Manual (repair manual). Page 114

Read Panasonic CS-VE9NKE / CS-VE12NKE / CU-VE9NKE / CU-VE12NKE Service Manual online

114 
9  Remove the compressor and heat charger tank. 
Cut the bands (2 locations) which fix the compressor to the heat charger tank. 
 
 
 
Remove the clamp and separate the compressor and heat charger tank. 
 Note on disassembly: Remove the heat charger tank sensor when replacing the heat charger tank. 
 
 
 
16.2.8  Heat Charger () Replacement Procedure 
16.2.8.1 Preparation 
1  Power-off the unit (remove plug and/or etc.,). 
2  Collect all refrigerant into the cylinder by reclaiming machine. 
3  As brazing work is involved, make sure the workshop and surrounding area is sufficient and safe. 
16.2.8.2 Process 
(Dismantling of the Parts) 
1  Remove control-board cover, top plate and front panel, pull out connecting wire, then remove side panel 
(right). 
2  Disconnect all connectors connected to control board. 
3  Remove solenoid coils of 2-way, 4-way and expansion valves. 
4  Disconnect of compressor connector, and remove control board. 
 
 
 
 
Heat charger: Part description is heat charge. 
 
 
 
 
 
Page of 127
Display