– 7 –
KV-HP29M83/M93/N63
RM-GA002
SECTION 2
WIRE DRESSING
CAUTION :
1. Make sure wires are kept away from sharp
edges, heatsinks & high temperature parts.
2. Do not over pull the wires during dressing
--> avoid disconnection of wires.
3. Prevent tie, cable from touching rear cover
or any enclosures by turning them away
from it --> to avoid rattle sound & prevent
cable tie from touching solder side of board.
W082
No. Part 
No. 
Description 
Block 
Remarks
 1 
1-910-026-28 
Lead Assy, Jumper 
A(Var) 
W016-W084(1)
 
 
 
 
W077-W065(0)
 2 
1-923-512-11 
WIRE UL 1007 
A(Com)  W082-W010(1)
 
 
AWG24 150MM ORG
W077
W016
P/N 1-923-512-11
Dress both Lead Assy,
Jumpers along edge of shield 
case
P/N 1-910-026-28
Keep Lead Assy,
Jumpers away from
R121
Conn Assy, 5P
YUV
W010
W084
W065
CN905
C903
C514
T501
Dress both Lead
Assy, Jumpers
around CN905, C903
and below Conn
Assy, 5P YUV
Dress Lead Assy, Jumper far
away from C514 and T501.
A002
No. Part 
No. 
Description 
Block  Remarks
 1 
1-923-082-52  Wire UL1007 
A(Var) 
W075-W018(1)
 
 
AWG24 140mm BLU
W018
A003
A222
A005
W075
P/N 1-923-082-52
Keep UL wire away from
heatsinks A005, A222, A003,
A002.
Dress UL
wire around
CN2103
CAUTION:
1.  Connector assy must be kept away from primary area.
Pin, wire A8204
4
CN8108
3
CN606
3
1) Insert Lead Assy, Speaker into CN4106. Ensure ACPower
 
Cord is behind Leady Assy, Speaker.
2) Next, dress Conn Assy, 8P into the 2 holders.
3) Insert and dress Conn Assy,6P MicSW into the 2 holders.
4) Dress AC Power Cord on K board using pin, wire A8204 as shown.
1
Conn Assy, 8P 
2
2
AC Power Cord is behind
Lead Assy, Speaker
Make sure connector end with
white taping is connected to
CN4106.
CN8202
CN4103(H1)/C
N4113(H2)
CN3102
CN4107
Conn Assy, 7P
CN4106
Conn Assy, 6P
MicSW
Dress AC Power Cord using pin, wire A8204.
Follow route of AC Power Cord as shown.
AC Power Cord is
behind wires
Dress AC Power Cord close
to board's surface
2-3.  Wire Dressing at A, K and H1 (Philippines) / H2 board
2-1.  Lead Assy, Jumper wire dressing at A board
2-2.  UL wire dressing at A board
Page of 78