KV-HP29M83 - Sony TV Service Manual (repair manual). Page 14

Read Sony KV-HP29M83 Service Manual online

– 13 –
KV-HP29M83/M93/N63
RM-GA002
Dress Cap Assy, High Voltage with Holder, HV cable combi
as shown.
Caution:
1) Make sure the specified position is being followed.
2) Position the Cap Assy, High Voltage in the inner ring of the
 
Holder, HV cable combi (see diagram)
DGC
HV cap
90°
TVSR requirement:
1.  Spacing between HV cable and other conductive
 
partís surface is 1mm/kV or more.
2.  Spacing between HV cable's and enclosure with
 
ventilation or the edge where terminal bracket
 
and rear cover meet: 10 mm or more.
CAUTION:
Production side please ensure that the portion of HV cable above the Holder,
HV Cable Combi is kept away from CRT's carbon area.
Also, portion of HV cable below the Holder, HV Cable Combi needs to be kept
away from conductive parts (DGC, rotation coil, CRT's carbon area, speaker
wire, etc).
Ensure forming of HV cable is OK and no unnatural curve occurs.
Do not twist or loop the cable.
CRT's carbon
area
Dress Holder, HV Cable Combi to Cap
Assy, High Voltage
230 ± 5 mm
Holder, HV cable combi
DGC
Inner Ring
Min. distance = 1mm/kV
Min. distance = 1mm/kV
Min. distance =
1mm/kV
Keep distance of HV cable
from other wires, conductive
parts and
CRT's carbon area
CRT's carbon
area
Install AC cord holder to AC power cord at specified position as shown.
650 ± 5mm 
Hook AC Power Cord into CRT
support's hook
Dress behind
boss
Make sure AC cord is
straight between boss and
holder
Beznet
CAUTION
Attach Purse Lock (S)
Ø 8 in to rear cover
 
Keep AC cord away
from heatsinks
Attach AC cord onto holder and
insert to bottom cover
Make sure AC cord is behind
beznet and above mounted
boards when docking chassis
--> avoid it from being trapped
between chassis and beznet
2-17.  HV Cap Assy wire dressing
2-18.  AC Power Cord Wire Dressing
Page of 78
Display