KV-HG21M80 - Sony TV Service Manual (repair manual). Page 13

Read Sony KV-HG21M80 Service Manual online

– 12 –
KV-HG21M80/M88
RM-GA002
2-14.  Lead Assy, G2 & Focus dressing
2-15.  Conn Assy, 7P, UL Wire (1-923-000-81), Lead Assy, Earth & Rotational Coil Conn dressing
 
 
 
 
 
 
Purse lock dia.5
FBT 
(G2)
FBT 
 
 
A      B     C
 
A    B     C    
 
 
DY
90
Dress Earth Assy, Coating, Lead Assy, G2 & Focus with purse lock Purse Lock Ø5. as shown
Note : Keep Lead Assy, G2 away from HV Cable (min 1mm/kV)
 
Ensure Lead Assy, G2 is kept away from heat sinks
(Focus)
ECA
CN704(C) CN705(C) CRT
SOCKET
Lead Assy, Focus
Lead Assy, G2
Purse Lock, dia.5
Figure b
Conn. Assy, 5P
Lead Assy,
Focus
Earth Assy,
Coating
Rear view of Lead Assy, Focus & G2,
Lead Assy,
G2
Use this as a reference to dress
ECA, Lead Assy, Focus & G2.
Dress tight at the portion to avoid
wire touches rear cover .
Note : Keep Lead Assy, Earth away from heat sinks.
Note : Keep Lead Assy, Earth away from heat sinks.
Rotation
al Coil
Conn Assy, 7P
Keep Lead Assy, Earth away from heat
Purse Lock Ø5 Lead Assy, Earth
Keep Lead Assy, Earth away from heat
Lead Assy, Earth
Conn Assy, 7P
Purse Lock Ø5
UL Wire (1-923-000-81)
Purse Lock Ø5
Purse Lock
Rotation Coil
Rotation Coil
A: Conn Assy, 7P
B: Lead Assy, Earth
C: UL Wire (1-923-000-81)
D: Rotational Coil Conn
A: Conn Assy, 7P
B: Lead Assy, Earth
C: UL Wire (1-923-000-81)
Non-Rotational Coil Models
Rotational Coil
Dress Conn Assy, 7P, UL Wire (1-923-000-81) and Lead Assy,
with purse lock, Ø5 as shown.
Dress Conn Assy, 7P, UL Wire (1-923-000-81), Lead Assy, 
Earth and Rotational Coil Conn with purse lock, Ø5 as shown.
Non-Rotational Coil Models
Rotational Coil Models
Keep Lead Assy, G2
away from Heat
Keep Lead Assy,
G2
away from HV
TVSR Requirement :
1. Spacing between HV cable and other conductive part’s surface is
1mm/kV or more.
2. Spacing between HV cable's and enclosure with ventilation or the edge
where terminal bracket and rear cover meet: 10 mm or more.
CAUTION:
Do not overpull the wires during dressing --> avoid disconnection 
of wire.
CAUTION:
Do not overpull the wires during
dressing --> avoid disconnection
of wires.
UL Wire (1-923-000-81)
Wire from
Rotation coil
Figure a
Figure c
Figure d
Safety