KV-HG21M80 - Sony TV Service Manual (repair manual). Page 12

Read Sony KV-HG21M80 Service Manual online

– 11 –
KV-HG21M80/M88
   RM-GA002
2-12.  Lead Assy, Speaker (Left), AC Power Cord and Front Control wire dressing
2-13.  DY Conn & Conn Assy, 5P (200V) dressing
1) Insert Lead Assy, Speaker (Left) followed by AC Power Cord into CRT support's hook.
 
Note : Ensure wires do not come out from hook.
 
 
Keep wires away from heat sink and other high temperature parts.
2) Make sure Front Control wire lie flat on bottom cover and dressed around AC Power Cord.
 
Note : Keep Front Control Wire away from heat sinks and other high temperature parts.
3) Ensure Tweeter's tab is facing inside (towards CRT).
 
Note : Avoid wire being sandwich while docking rear cover.
1) Dress DY Conn along Conn Assy, 5P (200V) as shown.
2) Dress DY Conn and Conn Assy, 5P (200V) with Purse Lock Ø5.
  Note : Kept DY Conn & Conn Assy, 5P away from FBT area by a distance of 10mm or more.
 
H3 
 
 
 
 
 
 
 
 
1
2
DY
 
 
 
 
 
CAUTION : during Bottom
Front Control
Wire is placed
Earth Assy, Coating
Purse Lock Ø5
Conn Assy
5P
(200V)
DY
 Conn
Conn Assy, 5P
DY Conn goes above Conn Assy, 5P
DY Conn goes underneath of Earth
Assy, Coating and Conn Assy, 5P
Front Control wire possible to get trap at
edge where beznet and bottom cover meet.
1) To prevent this, temporary place wire
behind DGC
Tweeter's
Insert Lead Assy, Speaker and
AC Power Cord into CRT
Ensure tweeter's
tab is facing
inside (towards
CRT) to avoid
wire being
sandwich while
docking rear
Lead Assy, Speaker
Front Control
AC Power
Bottom
Make sure Front Control wire lie flat on bottom cover
and dressed around AC Power Cord as shown.
=> Keep wire away from nearby heatsink.
Keep wires away from heatsink
CRT
Insert AC Power Cord in CRT support's
Make sure DY Conn is on the
right side of Earth Assy,
Purse Lock Ø5
≥ 10mm
Use heat sink height to
estimate purse lock location
Dress DY Conn and Conn Assy, 5P
(200V) with Purse Lock Ø5.
TVSR Requirement :
All wires must be kept away from
FBT area by a distance of 10mm or
more.
CAUTION:
Do not overpull the wires during dressing --> avoid disconnection 
of wire.
CAUTION:
Do not overpull the wires during dressing --> avoid disconnection 
of wire.
3
Page of 65
Display