Read Sony KV-DA292M86 Service Manual online
KV-DA292M86
RM-W105
– 14 –
2-20. HV cap assy wire
2-21. Dressing of Lead Assy, G2+Focus at Terminal Bracket
2-22. Dressing of Lead Assy, Focus and G2
2-23. Dressing of AC Power Cord
1) Dress HV cap assy with HV Holder as shown
Note: Make sure the specified position is being followed.
2) Dress HV holder at DGC with purse lock dia. 9 as shown
Note: Make sure the specified position is being followed.
2) Dress HV holder at DGC with purse lock dia. 9 as shown
1) Dress Lead Assy, G2 to 4 Hook at terminal bracket as shown
2) Dress Lead Assy, Focus to 2 Hook at terminal bracket as shown
Note: Keep minimum distance of 10mm between Lead Assy, G2 and
high voltage portion of FBT
2) Dress Lead Assy, Focus to 2 Hook at terminal bracket as shown
Note: Keep minimum distance of 10mm between Lead Assy, G2 and
high voltage portion of FBT
Dress the Conn Assy, 4P, Lead Assy, G2 + Focus with pin
lead coating, A9003 as shown
lead coating, A9003 as shown
Install AC cord holder to AC power cord at specified
position as shown.
position as shown.
TVSR requirement:
1. Spacing between HV cable's conductor and conductive
1. Spacing between HV cable's conductor and conductive
part's surface is 1mm/kV or more (10 mm min.)
2. Spacing between HV cable's conductor and enclosure
with ventilation or the edge where terminal bracket and
rear cover meet: 10 mm or more.
rear cover meet: 10 mm or more.
TVSR Requirement:
- Keep HV lead away from conductive parts 1mm/kV
- Keep HV lead away from conductive parts 1mm/kV
Dress Lead Assy, Focus and G2
Terminal Bracket
Lead Assy, Focus
Lead Assy, G2
Lead Assy, G2
Dress only Lead Assy, G2
at these 2 hook
Keep minimum distance of 10mm from Lead
Assy, G2+Focus to edge of terminal bracket
Assy, G2+Focus to edge of terminal bracket
Lead Assy, Focus
> 10mm
10mm
Dress AC cord
onto stopper
Insert AC cord holder
to terminal bracket
AC cord holder
200mm + 5mm
45
o
DGC
Min distance = 1mm/kV
HV Cap assy at ring which is
further away from DGC
DGC band
HV cap
HV holder
Purse lock dia.9
HV Holder
Use the position of crossing
between DGC and earth
coatingassy as a guideline to
dress HV holderwith purse lock
Earth coating assy wires
Gate of HV
Holder holder
Ensure that gate of HV Holder
is dressed with purse lock
near the DGC to keep HV
cable away from DGC and
Earth coating assy.
(Minimum distance = 1mm/kV)
--> TVSR requirement.
Make sure DGC is not
trapped at gate opening.
is dressed with purse lock
near the DGC to keep HV
cable away from DGC and
Earth coating assy.
(Minimum distance = 1mm/kV)
--> TVSR requirement.
Make sure DGC is not
trapped at gate opening.
270 + 5 mm
HV Holder
Ring
Purse lock
Gate (2 positions) of
HV holder
DGC
10mm
Avoid stress on Lead
Assy, G2+Focus
Pin Lead Coating,
A9003
A9003
Conn Assy, 4P
Lead Assy, G2
Lead Assy, Focus
Lead Assy,
Focus
Focus
CAUTION:
Ensure All wires do not touch
to solder side of VM PWB to
avoid scratch on the wire.
Ensure All wires do not touch
to solder side of VM PWB to
avoid scratch on the wire.
Click on the first or last page to see other KV-DA292M86 service manuals if exist.