KV-29FS100 (serv.man4) - Sony TV Service Manual (repair manual). Page 14

Read Sony KV-29FS100 (serv.man4) Service Manual online

— 15 —
KV-29FS100/29FV300/34FS100/
34FV250/38FV250
2-3.  FOCUS
1.  Input monoscope signal.
2.  Set user controls to normal.
3.  Set video mode to STANDARD.
4.  Set the PICTURE to maximum.
5.  Adjust at 325 Mark for best center/corner focus balance.
6.  Receive an entire white signal.  Make sure Magenta Ring is at an 
acceptable level.
Focus
Screen (G2)
35
325
35 MARK
325 MARK
CENTER
CIRCLE
2-4.  SCREEN (G2)
1.   Input dot pattern from the pattern generator.
2.   Set the user controls to NORMAL.
3.  Attach the G2-Jig to the C Board.
4.  Adjust RCUT, GCUT, BCUT, and SBRT in service mode with an 
oscilloscope so that voltages on the red, green, and blue cathodes 
are 170 ± 4.0Vdc. 
5.  Observe the screen and adjust SCREEN (G2) VR  to obtain the 
faintly visible background of dot signal.
6.  Push the TEST + JUMP (+ Channel) to cut off the signal.  The screen 
should be bright or dark.  Brightness of raster must be increased 
when adjusting.
7.  Adjust screen VR until the screen is slightly cut off, or scarcely lights 
up.  A signal cannot be seen when the brightness of the raster is high.
8.  Push the JUMP again to release the cut off.
pedestal
GND
170Vdc
 170 + 4.0 Vdc
2-5.  WHITE BALANCE ADJUSTMENTS
����
��� �����
����
��� ������
�������
����
��� �����
��
�������
���� ����� �����
��
�������
����
���� �����
��
�������
���� ��� �������
��
�������
���� ����� �������
��
�������
���� ���� �������
��
���
����
��� ������
87
1.  Set program palette to STANDARD and push RESET.
2.  Input an entire white signal.
3.  Set to Service Adjustment Mode.
4.  Set the PICTURE and BRIGHT to minimum.
5.  Adjust with SBRT if necessary.
6.  Set RCUT to “14”.
7.  Select GCUT and BCUT with  3 and  5 .
8.  Adjust by pressing  1 and  4 for the best white balance.
9.  Set the PICTURE and BRIGHT to maximum.
10. Select GDRV and BDRV with  and  .
11. Adjust with 3 and 6 for the best white balance.
12. Write into the memory by pressing  3 then  5.
13. Repeat steps 1-12 for GDR4, BDR4, GCU4 and BCU4 using      
Video 4 input. 
*  Use values from Sub Contrast Adjustments
White balance should be adjusted after Sub Contrast because 
RDRV is also used in Sub Contrast Adjustment. (See page 22).
Page of 85
Display

Click on the first or last page to see other KV-29FS100 (serv.man4) service manuals if exist.