KV-29FS100 (serv.man4) - Sony TV Service Manual (repair manual). Page 12

Read Sony KV-29FS100 (serv.man4) Service Manual online

— 13 —
KV-29FS100/29FV300/34FS100/
34FV250/38FV250
2-2.  CONVERGENCE
Preparation:
•  Perform FOCUS, V. LIN and V. SIZE adjustments.
•  Set BRIGHTNESS control to minimum.
•  Input dot pattern.
B
G
R
Center dot
V.STAT magnet
RV701 V.STAT
R   G   B
2-2-1.  VERTICAL AND HORIZONTAL STATIC 
CONVERGENCE
1.  Adjust V. STAT magnet to converge red, green and blue dots in the 
center of the screen (Vertical movement).
  Tilt the V. STAT magnet and adjust static convergence to open or 
close the V. STAT magnet.
2.  When the V. STAT magnet is moved in the direction of arrow a and b, 
red, green, and blue dots move as shown below:
B
R
G
B
R
G
R G
B
G
R
B
G
B
R
B G
R
1
2
3
a
b
a
b
b
b
a
a
b
b
a
b
a
b
2-2-2.  OPERATION OF BMC (HEXAPOLE) 
MAGNET
The respective dot positions resulting from moving each magnet interact, 
so perform adjustment while tracking.
1  Use the V.STAT tabs to adjust the red, green, and blue dots so they 
line up at the center of the screen (move the dots in a horizontal 
direction).
R G
B
R G B
R
G B
R G B
R G B
R G B
2-2-3.  Y SEPARATION AXIS CORRECTION 
MAGNET ADJUSTMENT
1.  Input cross-hatch pattern, adjust PICTURE to minimum and 
BRIGHTNESS to normal.
2.  Adjust the deflection yoke upright so it touches the CRT.
3.  Adjust so that the Y separation axis correction magnet on the neck 
assembly is symmetrical from top to bottom (open state).
BMC MA
GNET
PURITY
V.STAT
4.  Return the deflection yoke to its original position.