KP-57WV600, KP-57WV700, KP-65WV600, KP-65WV700 - Sony TV Service Manual (repair manual). Page 7

Read Sony KP-57WV600 / KP-57WV700 / KP-65WV600 / KP-65WV700 Service Manual online

— 8 —
KP-57WV600/57WV700/
65WV600/65WV700
Display of Standby/Timer LED Flash Count
STAND BY Indicator
TIMER Indicator
POWER
STAND BY
TIMER
CHANNEL
Diagnostic items 
Flash count
Lamp OFF 3 sec.
Lamp ON 0.3 sec.
Lamp OFF 0.3 sec.
+B Overcurrent 
2 times
Low +B Overvoltage 
3 times
Vert. Deflection Stopped 
4 times
White Balance Failure 
5 times
Low +B OCP/OVP 
6 times
Horiz. Deflection Stopped 
7 times
Release of TIMER STAND BY indicator blinking
The TIMER/STANDBY indicator blinking display is released by turning OFF the power switch on the TV main unit or removing the plug from the 
power.
Self-Diagnosis Screen Displays
In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off occasionally or when the screen 
disappears occasionally, there is a screen display on whether the malfunction occurred or not in the past (and whether the detection circuit operated 
or not) in order to allow conÞ rmation.
      
Screen Display Method
Quickly press the remote command button in the following order from the standby state.
  Display  
  Channel  5   
  Sound Volume* 
_
  
  Power ON 
 
 
 
 
 
*Note that this differs from entering the service mode (sound volume  +  )
 
 SELF DIAGNOSIS
 2: +B OCP  
0
 3: +B OVP  
0
 4: VSTOP  
0
 5: AKB   
1
 6: LOWB   
0
 7: H-STOP  
0
 101: WDT  
24
Self-Diagnosis Screen Display
The results display is not automatically cleared.  In case of repairs and after repairs, check the self-diagnosis screen and be sure to return the 
results display to “ 0 ”. 
If the results display is not returned to “ 0 ” it will not be possible to judge a new malfunction after completing repairs.
Method of Clearing Results Display
1.  Power off (Set to the stanby mode.)
2.   Display  
  Channel  5   
  Sound Volume  +   
  Power ON (Service Mode) 
3.  Channel  8   
   ENTER  (Test reset = Factory preset condition)
Method of Ending Self Diagnosis Screen
When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main unit.
Numeral “0” 
means that no fault was detected.
Numeral “1” 
means a fault was detected one 
time only.
Page of 127