KP-57WV600, KP-57WV700, KP-65WV600, KP-65WV700 - Sony TV Service Manual (repair manual). Page 6

Read Sony KP-57WV600 / KP-57WV700 / KP-65WV600 / KP-65WV700 Service Manual online

— 7 —
KP-57WV600/57WV700/
65WV600/65WV700
SELF-DIAGNOSTIC FUNCTION
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY/TIMER LED will automatically begin to ß ash. The number 
of times the LED ß ashes translates to a probable source of the problem. A deÞ nition of the STANDBY/TIMER LED ß ash indicators is listed in the 
instruction manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review 
the failure occurrence data stored in memory to reveal past problems and how often these problems occur.
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will ß ash a set number of times to indicate the possible cause of the problem. If there is more than 
one error, the LED will identify the Þ rst of the problem areas.
Results for all of the following diagnostic items are displayed on screen. If the screen displays a “0”, no error has occurred.
Diagnostic Item
No. of times
STANDBY /
TIMER lamp
flashes
Display
Result
Probable Cause Location
Detected Symptoms
Power does not turn on
Does not light
_______
Power cord is not plugged in.
Fuse is burned out (F501). (A Board)
Power does not come on.
No power is supplied to the TV.
AC Power supply is faulty.
+B Overcurrent (OCP)*
2 times
2:0 or 2:1
H.OUT(Q8024) is shorted. (D Board)
+B PWM (Q8035) is shorted.
(D Board)
Power does not come on.
Load on power line shorted.
Low +B Overvoltage (OVP)
3 times
3:0 or 3:1
IC6504 is faulty. (D Board)
Has entered standby mode.
Vertical Deflection Stopped
4 times
4:0 or 4:1
15V is not supplied. (D Board)
IC8003 is faulty. (D Board)
Has entered standby mode after
Horizontal raster.
Vertical deflection pulse is stopped.
Power line is shorted or power
supply is stopped.
White Balance Failure
(not balanced)
5 times
5:0 or 5:1
Video OUT(IC9101, IC9201, IC9301)
is faulty. (CR, CG, CB Board)
CRTdrive (IC2801) is faulty. (B Board)
G2 is improperly adjusted.**
No raster is generated.
CRTcathode current detection
reference pulse output is small.
LOW +B OCP/OVP
(overcurrent/overvoltage)***
6 times
6:0 or 6:1
+5 line is overloaded. (A, B, M Boards)
+5 line is shorted. (A, B, M Boards)
IC504 is faulty. (A Board)
No picture
Horizontal Deflection
Stopped
7 times
7:0 or 7:1
No picture
* If a +B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously. The symptom that is diagnosed first by the
microcontroller is displayed on the screen.
** Refer to Screen (G2) Adjustment (Fine Adjustments) in Section 2 of this manual.
*** If STANDBY/STEREO LED flashes six (6) times, unplug the unit and wait 10 seconds before performing the adjustment.
Self Diagnosis
Supported model
Page of 127
Display

Click on the first or last page to see other KP-57WV600 / KP-57WV700 / KP-65WV600 / KP-65WV700 service manuals if exist.