KF-E42A10, KF-E50A10 (serv.man3) - Sony TV Service Manual (repair manual). Page 10

Read Sony KF-E42A10 / KF-E50A10 (serv.man3) Service Manual online

– 10 –
KF-E42A10/E50A10
RM-GA004
4. Self-diagnosis screen displays
– In cases of malfunctions where it is not possible to determine the symptom such as when the power goes off
occasionally or when the screen disappears occasionally, there is a screen display on whether the malfunction occurred
or not in the past (and whether the detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
– Quickly press the remote command button in the following order from the standby state.
– The results display is not automatically cleared. In case of repairs and after repairs, check the self-diagnosis screen and
be sure to return the results display to "0".
– If the results display is not returned to "0" it will not be possible to judge a new malfunction after completing repairs.
<Method of Clearing Results Display>
<Method of Ending Self-Diagnosis Screen>
– When ending the self-diagnosis screen completely, turn the power switch OFF on the remote commander or the main
unit.
5. Self-Diagnosis function operation
1
:
Lamp_ERROR
When the lamp is broken.
2
:
lamp temp over
When the inside temperature sensed with IC7021, IC7180 and IC603 mounted on HB board, S2
board and C board respectively exceed the threshold, the lamp turns off.
3
:
lamp cover
When the lamp cover is opened the connector of the lamp is not fixed, the lamp turns off.
4
:
FAN
When any FAN (FAN1~FAN4) is stopping or harness is not connected correctly, the lamp turns
off.
5
:
Lamp Driver
When the ballast is not working with high voltage, the lamp turns off.
6
:
Low B error
When the voltage B_12V is low, TVM(TV u-com) detects it and makes turn off the lamp.
Channel
Vol
Be aware that this differs from
the method of entering the
service mode (Vol +).
DISPLAY
5
-
POWER
1
: LAMP_ERROR
0
 2
: LAMP_TEMP
0
 2
: TEMP_ERROR
0
No use
3
: LAMP_COVER
0
 4
: FAN_ERROR
0
5
: LAMP_DRIVER
0
6
: LOWB_ERROR
0
7
: AUDIO_PROT
0
No use
8
: D_OVP
0
No use
 10 : ATSC_OVP
0
No use
SELF CHECK
- Numeral "1" means a fault was detected one time
- Numeral "0" means that no fault was detected
1. Power off (Set to the standby mode)
2.
Channel
Vol
3. Channel
8
ENTER
DISPLAY
5
-
POWER
Page of 78
Display

Click on the first or last page to see other KF-E42A10 / KF-E50A10 (serv.man3) service manuals if exist.