DPF-VR100, DPF-XR100, DPF-XR80 - Sony Other Service Manuals Service Manual (repair manual). Page 11

Read Sony DPF-VR100 / DPF-XR100 / DPF-XR80 Service Manual online

DPF-XR80/XR100/VR100
– 11 –
– ENGLISH –
2. WRITING OF FIRMWARE
The following procedures are used in DPF-XR100 model.
Conduct the same adjustment for the other models.
2-1.  METHOD OF WRITING OF FIRMWARE
Execute writing the latest firmware when the MAI-010 PC Board Assy 
(Service) was replaced.
If the firmware is not written, normal operation is not done.
Note:  Execute the following procedure in order: WRITING OF SUB CPU, PRE 
UPDATE, WRITING OF FIRMWARE and CHANGE THE DESTINA-
TION.
Preparation
1.  Ready the SD card or SDHC card which capacity is 32GB or less. 
(hereinafter referred to as “the SD card”) 
2.  Format  it  by  using  “SD  Formatter  3.0  (or  later)  for  SD/SDHC/
SDXC”  providing via a URL below.
http://www.sdcard.org/consumers/
Note:  Do not use the SD card formatted without tool above. Updater may cause 
abnormal operations.
3.  Download the following three files from the ESI homepage.
•  DPF_ALEX99_2010XXXX.zip (for pre update)
•  SDUPDATER_2010XXXX.zip (photo frame firmware)
•  SUBCPUXX_2010XXXX.zip (sub CPU)
Note:  Download latest files.
4.  Decompress the zip files downloaded.
2-1-1. WRITING OF SUB CPU
Procedure
1.  Copy  SUBCPUXX.VUP  created  by  the  decompression  of 
SUBCPUXX_2010XXXX.zip onto the root directory of the SD 
card. (most significant hierarchy)
Note:  Do not copy the file except SUBCPUXX.VUP.
2.  Insert the SD card into the SD card slot on the back surface of the 
photo frame.
3.  Insert the plug of the AC adaptor of accessories into outlet.
4.  Insert the plug of the AC adaptor into DC IN 9V terminal on the 
back surface of the photo frame while pressing the [VIEW MODE] 
button to turn on the power.
5.  Release the [VIEW MODE] button when a “S-Frame” logo appears.
6.  When the maintenance mode screen appears, move the cursor to 
“Update firmware” by pressing the [V] [v] button, and press the 
[ENTER] button. (Fig. 2-1-1)
8.  After displaying a version screen, confirm whether the “Updated 
version” is the same as the version that has been described in the 
homepage of ESI, and press the [ENTER] button. (Fig. 2-1-3)
9.  After displaying “Completed.”, unplug the AC adapter to turn off 
the power. (Fig. 2-1-4)
Note:  Power cannot be turned off by pressing the 1 (on/standby) button.
10.  Press the [RESET] button on the back surface of the photo frame 
by using small needle.
11.  Insert the plug of the AC adaptor into DC IN 9V terminal on the 
back surface of the photo frame while pressing the [MENU] button 
and [ENTER] button to turn on the power.
12.  Release the [MENU] button and [ENTER] button when a “S-Frame” 
logo appears.
6.  When the maintenance mode screen appears, move the cursor to 
“Update firmware” by pressing the [V] [v] button, and press the 
[ENTER] button. (Fig. 2-1-7)
7.  When a “Checking the update file.” appears, release the [ENTER] 
button. (Fig. 2-1-8)
8.  When the version up screen appears, confirm the figure of “Updated 
version” is 99.99, and press the [ENTER] button. (Fig. 2-1-9)
13.  After displaying an initial screen of the service mode, move the 
cursor to “System Info” by pressing the [V] [v] button, and press 
the [ENTER] button. (Fig. 2-1-5)
15.  Press the [BACK] button to return to the initial screen of the service 
mode.
16.  Turn off the power pressing the 1 (on/standby) button for a second.
17.  Remove the SD card from the photo frame.
2-1-2. PRE UPDATE
Procedure
1.  Delete 
SUBCPUXX.VUP
 from the SD card.
2.  Copy  DPF_ALEX99.VUP  created  by  the  decompression   
of  DPF_ALEX99_2010XXXX.zip  in  the  folder  of  DPF_
ALEX99_2010XXXX onto the root directory of the SD card. (most 
significant hierarchy)
Note:  Do not copy the files except DPF_ALEX99.VUP.
3.  Insert the SD card into the SD card slot on the back surface of the 
photo frame.
4.  Turn  on  the  1  (on/standby)  button  while  pressing  the  [VIEW 
MODE] button.
5.  Release the [VIEW MODE] button when a “S-Frame” logo appears.
14.  Confirm whether the version of the “subcpu” of “Partition Info” is 
the same figure as the version of the firmware that has been described 
in the homepage of ESI. (Fig. 2-1-6)
Maintenance mode
Update firmware
Initialize system
Fig. 2-1-7
Fig. 2-1-8
Checking the update file.
Insert the memory card and
press [ENTER].
Fig. 2-1-9
Press [ENTER] to update
the firmware.
Updated version :99.99
Current version :1.00
Maintenance mode
Update firmware
Initialize system
Fig. 2-1-1
Fig. 2-1-2
Checking the update file.
Insert the memory card and
press [ENTER].
Fig. 2-1-3
Press [ENTER] to update
the firmware.
Updated version :1.04
Current version :1.04
Fig. 2-1-4
Completed.
Restart the Digital Photo Frame.
System Info
System Setting
Media Check
USB Host Test
Electric Test
Electric Test
Frame Angle : 0
CHECKSUM: XXXXXXXX (H)
DATE: SEP 9 2010 14:39:13
USB SERIAL NO: XXXXXXXX
DPF-XR100 (XX)
Fig. 2-1-5
Button Test
[ Test History ]
Card Test
Set Default
OK
OK
OK
USB Test
CEC Test
Format NAND
LCD W/B
R offset :0 B offset :0
[ Partition Info ]
subcpu : ver 01.04
updater : ver 1.00
uboot : 2010/08/30 11:09
dpf/demo : 2010/07/20 20:44:52
dpf/sound : 2010/07/20 11:20:14
dpf/other : 2010/09/07 16:31:20
OK
OK
OK
Fig. 2-1-6
7.  When a “Checking the update file.” appears, release the [ENTER] 
button. (Fig. 2-1-2)
Fig. 2-1-10
Completed.
Restart the Digital Photo Frame.
9.  When a “Completed.” appears, turn off the power pressing the 1 
(on/standby) button for about a second. (Fig. 2-1-10)
10.  Remove the SD card from the photo frame.