HDR-XR500, HDR-XR500E, HDR-XR500V, HDR-XR500VE, HDR-XR520, HDR-XR520E, HDR-XR520V, HDR-XR520VE (serv.man2) - Sony Movie Service Manual (repair manual). Page 10

Read Sony HDR-XR500 / HDR-XR500E / HDR-XR500V / HDR-XR500VE / HDR-XR520 / HDR-XR520E / HDR-XR520V / HDR-XR520VE (serv.man2) Service Manual online

1-3
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-XR500/XR500E/XR500V/XR500VE/
XR520/XR520E/XR520V/XR520VE_L2
E
E
E
E
E
E
E
E
E
E
E
E
E
E
Block
Function
6
1
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
9
1
9
4
9
4
9
5
9
6
Detailed
Code
3
0
0
0
0
1
0
2
0
3
1
0
1
1
1
2
2
0
0
1
0
0
0
2
0
0
0
0
Symptom/State
Reset position detection error on the
stepper iris initializing
Handshake correction function does not
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
work well. (With YAW angular velocity
sensor output stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure.
Shift lens overheating (Pitch)
Shift lens overheating (Yaw)
Abnormality of thermistor.
Abnormality when flash is being charged.
Fault of writing or erasing the
flash memory
BGM data error
GPS hardware error
Map area mount error
Self-diagnosis Code
Repaired b
y:
Correction
Open the lens barrier by turning on the power and turn power off
by putting battery off or pulling out power cord.  Turn power on
again and check the iris blades in the lens move precisely.
In case of the iris blades doesn’t move, inspect the iris motor
drive outputs (CN1002 pins qs to qg on VC-557 board).
In case of the iris blades move, inspect the iris reset sensor
outputs (CN1002 pins 1 to 3 on VC-557 board).
Inspect PITCH angular velocity sensors (SE6601 on the FR-298
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE6601 on the FR-298
board) peripheral circuits.
Refer to [1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC5501 on the VC-557 board).
Replacement of lens block. If an error occurs again, replace the
VC-557 board. (Note 2)
Refer to [1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
Refer to [1-5-4. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
Checking of flash unit or replacement of flash unit.
Inspect the flash memory (IC2101 on the VC-557 board).
Inspect the flash memory  (IC2101 on he VC-557 board). If it is
OK, check the CPU (IC1701 on the VC-557 board).
XR500V/XR500VE/XR520V/XR520VE
Check whether the flexible board of the GPS module is broken,
and check whether it is inserted imperfectly. If there is no
problem the flexible board, inspect or replacement of the GPS
module.
XR500V/XR500VE/XR520V/XR520VE
Inspect or replacement of the hard disk drive.
Note 2 : When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment
items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
The changed portions from
Ver. 1.0 are shown in blue.
Ver. 1.1  2009.02
Page of 116
Display