6-23
HDR-UX3E/UX5/UX5E/UX7/UX7E_ADJ
8.
CAMERA Adjustment 4
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. F No. & ND Light Quality Standard Data Input
3. Mechanical Shutter Adj.
4. Linear Matrix Adj.
5. Picture Frame Setting (Color Reproduction Adjustment Frame)
6. Picture Frame Setting (All White Frame)
7. AWB Standard Data Input
8. LV Standard Data Input
9. AWB Adj.
10. AWB Check
11. Color Reproduction Adj. & Check (Indoor HD)
12. Color Reproduction Check (Indoor SD)
13. Color Reproduction Check (Outdoor HD, Outdoor SD)
14. Picture Frame Setting (Center Frame)
15. MAX GAIN Adj.
16. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 4.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) If “1. Data Setting during Camera Adj.” completed success-
fully, and the items from “2. F No. & ND Light Quality Stan-
dard Data Input” to “4. Linear Matrix Adj.” will be executed.
4) Upon successful completion of the “4. Linear Matrix Adj.”,
the following screen is displayed during the execution of “5.
Picture Frame Setting (Color Reproduction Adjustment
Frame)”. Set the subject in accordance with the message.
5) If the [OK] button is clicked, the following screen will appear,
and then adjust the zoom and the camera direction to set the
picture frame. After the setting finished, click the [End] but-
ton.
The buttons on this screen provide the following functions:
[Save the position] button
Saves the camera zoom and focus position data.
[Load the position] button
Reads the camera zoom and focus position data saved last and
moves the camera zoom and focus to that position.
Note 1:
 The zoom and focus position data are saved with “HDR-
UX5_ZoomFocusData.txt” file name in the same holder
as the Automatic Adjustment Program.
No position data can be read if this file is moved or de-
leted.
Note 2:
Only the latest position data can be saved. If the [Save
the position] button is clicked, the latest data are saved
over writing the previous data.