HDR-UX1, HDR-UX1E (serv.man2) - Sony Movie Service Manual (repair manual). Page 10

Read Sony HDR-UX1 / HDR-UX1E (serv.man2) Service Manual online

1-3
HDR-UX1/UX1E_L2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
1-4-3. Self-diagnosis Code Table
C
C
C
C
C
E
E
E
E
E
E
E
E
Block
Function
0
4
1
3
1
3
2
1
3
2
2
0
3
1
6
1
6
1
6
2
6
2
9
1
9
4
Detailed
Code
0
0
0
1
0
2
0
0
6
0
0
0
0
0
1
0
1
1
0
0
0
1
0
1
0
0
Symptom/State
Non-standard battery is used.
“Memory Stick Duo” is unformatted.
“Memory Stick Duo” is broken.
Disc access error
Condensation.
Difficult to adjust focus
(Cannot initialize focus)
EEPROM data are rewritten.
Drive fault
Zoom operations fault
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
initialization of the zoom lens occurred
simultaneously.
Handshake correction function does not
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
work well. (With YAW angular velocity
sensor output stopped.)
Abnormality when flash is being charged.
Fault of writing to or erasing the
flashmemory
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Clean the disc with the supplied cleaning cloth.
Use a compatible disc with the camcorder.
Remove the disc, and insert it again after one hour.
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin ql, wa of
CN5201 on the LD-208 board). If it is OK, check the focus
motor drive IC (IC5204 on the LD-208 board).
Make EEPROM data correct value.
Inspect or replacement of the mechanism deck, IC (IC4401 on
the MD-131 board) and drive block.
Inspect the lens block zoom MR sensor (pin qh, qk of CN5201
on the LD-208 board) when zooming is performed when the
zoom lever is operated, and the zoom motor drive circuit
(IC5204 on the LD-208 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect PITCH angular velocity sensors (SE6801 on the CM-074
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE6802 on the CM-074
board) peripheral circuits.
Checking of flash unit or replacement of flash unit. 
(Note)
Inspect the flash memory (IC4302 on the MD-131 board).
Ver. 1.3  2007.09
The changed portions from
Ver. 1.2 are shown in blue.
Note: After repair, be sure to perform “1-5. PROCESS AFTER FIXING FLASH ERROR”.
1-5. PROCESS  AFTER  FIXING  FLASH  ERROR
When “FLASH error” (Self-diagnosis Code E:91:01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is
changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Flash error code can be initialized by execution of “Clear All record-data”.
Note: For “Clear All record-data”, refer to Service Manual, ADJ (“6. Record Data” of “3-2. SERVICE MODE”).