HDR-HC9, HDR-HC9E (serv.man2) - Sony Movie Service Manual (repair manual). Page 11

Read Sony HDR-HC9 / HDR-HC9E (serv.man2) Service Manual online

1-4
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-HC9/HC9E_L2
E
E
E
E
E
E
E
E
E
E
E
Block
Function
6
1
6
1
6
2
6
2
6
2
6
2
6
2
6
2
6
2
6
2
9
1
Detailed
Code
1
0
1
1
0
0
0
1
0
2
0
3
1
0
1
1
1
2
2
0
0
1
Symptom/State
Zoom operations fault.
(Cannot initialize zoom lens.)
Focus lens initializing failure and zoom
lens initializing failure occur simulta-
neously.
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Shift lens initializing failure.
Shift lens overheating (Pitch).
Shift lens overheating (Yaw).
Abnormality of thermistor.
Abnormality when flash is being charged.
Self-diagnosis Code
Repaired by:
Correction
Inspect the zoom MR sensor of lens block (Pin w;, wa of CN5301
on the LD-221 board) when zooming is performed when the zoom
switch is operated and the zoom motor drive circuit (IC5404 on
the LD-221 board) when zooming is not performed.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
Inspect pitch angular velocity sensor (SE7202 on the CM-077
board) peripheral circuits.
Inspect yaw angular velocity sensor (SE7201 on the CM-077
board) peripheral circuits.
Refer to [1-7-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC5703 on the LD-221 board).
Refer to [1-7-2. E : 62 : 10 (Shift Lens Initializing Failure)
Occurred].
Refer to [1-7-3. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [1-7-4. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
Refer to [1-7-5. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
Checking of flash unit or replacement of flash unit. (Note)
1-6. PROCESS  AFTER  FIXING  FLASH  ERROR
When “FLASH error” (Self-diagnosis Code E:91:**) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash
is changed automatically to disabling charge and flash setting.
After fixing, this setting needs to be deactivated. Connect the adjustment remote commander (RM-95 or NEW LANC JIG) and perform the
following process.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data changes to “01”.
Note:
After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.
Page of 113
Display

Click on the first or last page to see other HDR-HC9 / HDR-HC9E (serv.man2) service manuals if exist.