1-3-2. Assembly of Air-leak Tester (Compressor type)
1.  Insert the tube with vacuum pad into the right side connector, and connect the compressor (0.40 MPa or more) to the left side connector.
 
to Compressor
Tube (Outside diameter 6mm)
2.  Remove the side-mounted screw, set the two dry-cell batteries (type 9V).
 
DC power supply can be use in place of the dry-cell batteries. (DC12 V to 24 V)
 
1-3-3. Assembly of Air-leak Tester (Hand Pump Type)
1.   Insert the tube with vacuum pad into the right side connector, and connect the hand pump to the left side connector.
 
2.  Remove the side-mounted screw, set the two dry-cell batteries (type 9V).
 
DC power supply can be use in place of the dry-cell batteries. (DC12 V to 24 V)
 
1-3-4. Operation of Pressure Indicator
 
• Perform the setting (Focus mode, -40.0 kPa)
1.  Press the MODE button for 3 seconds or more.
2.  Press the MODE button at 1 time.
3. Press 
the   button, and select the Foc mode.
4.  Press the MODE button at 1 time.
5. Press 
the   button, and change to “-40.0”.
6.  Press the MODE button at 6 times.
7.  Indicated value is changed to “FFF”.
• Initialize
Press the set button 5 times with holding down the MODE button.
1-3-5. The Switch of Air-leak Tester (Compressor Type)
Turn to the Right : Decrease in pressure
Turn to the Left   : Increase in pressure
Pressure Regulator Knob
Open
Close
Air Switch