1-4-2. Inspection Procedure (Hand Pump Type)
1.  Turn on the air-leak tester.
2.  Keep the vacuum pad by pressing it to the center of test hole on the camera.
 
OK
Tilt
NG
Test hole
Cover Tape (Microphone)
Microphone Sheet
Air leak
Caution :
Keep vacuum pad vertically by touching with finger. 
Do not keep pressing it to the camera.
Do not touch the tube during the measurement, or measurement
value may be changed.
Caution:
When performing air leak test, peel off the Microphone Sheet
(4-427-606-01) and stick Cover Tape (Microphone) (4-427-546-01).
After the test has been completed, peel off the Cover Tape
(Microphone) (4-427-546-01) and stick a new Microphone Sheet
(4-427-606-01).
Perform the measurement under no vibration.
It may cause the air-leak under the condition with vibration.
Body side
Panel side
3.  Press the hand pump slightly so that the indicated pressure value becomes to “-5.0”.
 
Few seconds later, decrease the pressure slightly. Therefore adjust the indicated pressure by pressing the hand pump.
Note: Perform the pressure adjustment by hand pump pushing amount.
   
If the pressure becomes too high, perform the adjustment again after removing the vacuum pad.
 
– ENGLISH –
4   The change value is getting settle, wait 120 seconds with keeping the pressure at around the -5.0kPa (within -0.0kPa to -10.0kPa).
Caution:  Do not operate the hand pump after settling the change value.
   
If operate the hand pump again, wait 120 seconds form then.
5.  Write the indicated value, leave for 1 minute, and check the pressure changes value is satisfied the following value by comparing between written 
indicated value and indicated value.
Body side
 
Specification value  0.32 kPa or less: OK
 
 
0.33 kPa or more: NG
Caution: Do not open the connector cover and the battery/memory card cover for two minutes after the leak test.
 
120 sec
60 sec
Measurement
Vacuum by hand pump
Stop hand pump
Measure this changed value.
One minute later, it is OK
if the value within 0.32 kPa.
Measure between -0.0 to -10.0
-40.0 kPa
0 kPa
-45.0 kPa
-50.0 kPa
Air
pressure
-0.0 kPa
FFF
-5.0 kPa
-10.0 kPa
Indicated
value
Panel side
 
Specification value  0.07 kPa or less: OK
 
 
0.08 kPa or more: NG
Caution: Do not open the connector cover and the battery/memory card cover for two minutes after the leak test.
 
120 sec
60 sec
Measurement
Vacuum by hand pump
Stop hand pump
Measure this changed value.
One minute later, it is OK
if the value within 0.07 kPa.
Measure between -0.0 to -10.0
-40.0 kPa
0 kPa
-45.0 kPa
-50.0 kPa
Air
pressure
-0.0 kPa
FFF
-5.0 kPa
-10.0 kPa
Indicated
value
Page of 43
Display

Click on the first or last page to see other HDR-GW55VE / HDR-GW77 / HDR-GW77E / HDR-GW77V / HDR-GW77VE (serv.man2) service manuals if exist.