HDR-GW55VE, HDR-GW77, HDR-GW77E, HDR-GW77V, HDR-GW77VE (serv.man2) - Sony Movie Service Manual (repair manual). Page 15

Read Sony HDR-GW55VE / HDR-GW77 / HDR-GW77E / HDR-GW77V / HDR-GW77VE (serv.man2) Service Manual online

HDR-GW55VE/GW77/GW77E/GW77V/GW77VE_L2
1-11
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens block zoom sensor signal (pin 5 of CN1001 on the 
VC-657 board) when zooming is performed when the zoom lever is 
operated, and the zoom motor drive circuit (IC5501 on the VC-657 
board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Turn the power on to open lens barrier. Disconnect the battery or power 
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens 
drive block (CN1001 pin qf, qg on VC-657 board).
If iris blades work normally, confirm that they are closing completely 
and confirm following item.
・  Case of the iris blades do not close normally Replace the lens block).
・  Case of “E: 61: 30” is appeared and iris blades closed completely.
  Confirm that communication with lens block is normal.
・  Case of LCD is not displayed normally Check that connection be-
tween CN7502 on CM-128 board and CN1004 on VC-657 board 
by FP-1524 flexible board.
・  Case of LCD is displayed normally Replace the lens block.
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Inspect PITCH angular velocity sensors (SE7501 on the CM-128 
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Inspect YAW angular velocity sensors (SE7501 on the CM-128 board) 
peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to [1-11-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred].
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Inspect the steadyshot circuit (IC5501 on the VC-657 board).
E
6
2
0
4
I m a g e   v i b r a t i o n   c o r r e c t i o n   d u r i n g
handshake function does not work.
Inspect the image vibration angular velocity sensors (SE7701 on the 
VC-657 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block. (Note 3) If an error occurs again, replace 
the VC-657 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to [1-11-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred].
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to [1-11-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred].
E
6
2
2
0
Abnormality of thermistor.
Refer to [1-11-4. E : 62 : 20 (Abnormality of Thermistor) Occurred].
E
9
1
0
1
Abnormality when flash is beingcharged.
Check or replace the flash or charging capacitor.
E
9
1
0
2
Abnormality of LED Video light.
Turn power off and turn power on again.
E
9
1
0
3
Abnormality of LED Video light  Tempera-
ture detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. 
E
9
4
0
0
Fault of writing or erasing the flash mem-
ory
Inspect the flash memory (IC8101 on the VC-657 board).
E
9
4
0
1
Internal flash memory fault
Inspect the flash memory (IC8101 on the VC-657 board).
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-657 board).
*
*
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
9
5
0
0
GPS hardware error
GW55VE/GW77V/GW77VE:
Check whether the FP-1530 flexible board is broken,and check 
whether it is inserted imperfectly.
If there is no problem the flexible board, inspect or replacement of 
the GP-055 board.
E
9
6
0
0
Map area mount error
GW55VE/GW77V/GW77VE:
Inspect or replacement of the VC-657 board.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
1-11. METHOD OF COPING WITH SHIFT LENS ERROR
VC-657 BOARD (SIDE A)
C5526
C5527
C5528
C5529
R5505
IC5501
Fig. 1
Measurement points on the VC-657 board
*
*
Page of 43
Display

Click on the first or last page to see other HDR-GW55VE / HDR-GW77 / HDR-GW77E / HDR-GW77V / HDR-GW77VE (serv.man2) service manuals if exist.