HDR-CX405, HDR-CX440, HDR-PJ410, HDR-PJ440 - Sony Movie Service Manual (repair manual). Page 12

Read Sony HDR-CX405 / HDR-CX440 / HDR-PJ410 / HDR-PJ440 Service Manual online

Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
4 1
0 0
Abnormality of the wireless LAN
module or CPU
The peripheral circuit of between CPU and wireless LAN
module may be faulty.
Replace the board that contains this peripheral circuit.
E
6 1
0 0
Difficult to adjust focus
(Cannot initialize focus)
Turn power off and turn power on again. When this error is
not cleared, the focus control signal for the lens block may
be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
6 1
1 0
Zoom operations fault
(Cannot initialize zoom lens)
Turn power off and turn power on again. When this error is
not cleared, operate the zoom lever and check following
items.
• When zooming is performed, the zoom control signal
for the lens block may be faulty.
• When zooming is not performed, the zoom motor
drive circuit may be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
6 1
1 1
Focus or zoom fault
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis
code.
E
6 1
3 0
Reset position detection error on the
stepper iris initializing
Turn the power on to open lens barrier. Disconnect the bat-
tery or power cord, and then connect again. And confirm
that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive cir-
cuit in lens drive block. If iris blades work normally, con-
firm that they are closing completely and confirm following
items.
• Case of the iris blades do not close normally. Replace
the lens block.
• Case of “E: 61: 30” is appeared and iris blades closed
completely. Confirm that communication with lens
block is normal.
• Case of LCD is not displayed normally, check that
connection between imager board and main board.
• Case of LCD is displayed normally, replace the lens
block.
E
6 1
3 1
Error in detection of the Reset Posi-
tion at the time of Stepper IR Filter
initialization
Check the signal line connection between the lens block and
the lens control circuit.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
6 2
0 0
Steadyshot does not work well.
(With PITCH angular velocity sen-
sor output stopped)
The peripheral circuit of the PITCH angular velocity sensor
may be faulty.
Replace the board that contains this peripheral circuit.
E
6 2
0 1
Steadyshot does not work well.
(With YAW angular velocity sensor
output stopped)
The peripheral circuit of the YAW angular velocity sensor
may be faulty.
Replace the board that contains this peripheral circuit.
E
6 2
0 2
Abnormality of IC for steadyshot.
Check signal line connections from CPU through steady-
shot IC to PITCH/YAW drive.
When there is no problem with the connections, replace the
board that contains this peripheral circuit.
E
6 2
0 3
Communication error of steadyshot
IC and CPU
The steadyshot circuit may be faulty.
Replace the board that contains this peripheral circuit.
E
6 2
0 4
Image vibration correction during
steadyshot does not work.
The image vibration angular velocity sensor (ROLL SEN-
SOR) peripheral circuit may be faulty.
Replace the board that contains this peripheral circuit.