HDR-CX405, HDR-CX440, HDR-PJ410, HDR-PJ440 - Sony Movie Service Manual (repair manual). Page 11

Read Sony HDR-CX405 / HDR-CX440 / HDR-PJ410 / HDR-PJ440 Service Manual online

Section 1
Trouble Shooting
1-1. 
Self-diagnosis Function
1-1-1. 
Self-diagnosis Function
If an error occurs in this unit, the self-diagnosis function starts working and a code consisting of one alphabet and a four-
digit number appears on the LCD. Classification of persons in charge, classification of faulty blocks, and details of errors
can be checked by referring to this indication of five alphanumeric characters in the self-diagnosis code table.
The history of past errors can be checked in “Usage and Diag record” on the DATA tab of the Adjust Manual.
The self-diagnosis function is also described in the operation manual.
1-1-2. 
Note on the Function of Boards
The boards and functions used in this model are mentioned in the following table.
Board
Function
CM board
Imager
MM board
Internal memory
WF board
Wireless LAN module
PJ board
Projector
VC board
CPU, Power, Lens drive, 3-axis angular velocity sensor, Other function
1-1-3. 
Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
C
0 4
0 0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0 6
0 0
The battery pack temperature is
high.
Change the battery pack or place it in a cool place.
C
1 3
0 1
Memory card is unformatted or
memory card is broken.
Format the memory card.
Insert a new memory card.
C
1 3
0 2 
*1
Access error
Remove the power source. Reconnect it again and operate
the unit again.
C
1 3
0 3 
*1
Access error (External media)
Turn power off and turn power on again.
C
1 3
0 4 
*1
Abnormality of the drive (External
media)
Turn power off and turn power on again.
C
3 2
6 0
Difficult to adjust focus
(Cannot initialize focus)
Turn power off and turn power on again. When this error is
not cleared, the focus control signal for the lens block may
be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
E
2 0
0 0
Flash memory data are rewritten.
Make flash memory data correct value. 
*2
E
3 1
0 0 
*1
Abnormality of the drive
Turn power off and turn power on again.
Continued
*1:
Function of this code is not provided in this unit.
*2:
Start the Adjust Manual in the Adjust Station and execute the “Destination data write” on the ADJUST tab.
HDR-CX405/HDR-CX440/HDR-PJ410/HDR-PJ440
1-1
Page of 62
Display

Click on the first or last page to see other HDR-CX405 / HDR-CX440 / HDR-PJ410 / HDR-PJ440 service manuals if exist.