DEV-30, DEV-50, DEV-50V (serv.man2) - Sony Movie Service Manual (repair manual). Page 8

Read Sony DEV-30 / DEV-50 / DEV-50V (serv.man2) Service Manual online

DEV-30/50/50V_L2
1-4
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens block zoom sensor signal (pin eg of CN5002 on the 
LD-1009 board and pin eg of CN5102 on the LD-1010 board) when 
zooming is performed when the zoom lever is operated, and the zoom 
motor drive circuit (IC5701 on the VC-1016 board) when zooming is 
not performed.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Turn the power on. Disconnect the battery or power cord, and then 
connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive signal in lens 
drive block (pin wg, wh of CN5002 on the LD-1009 board and pin wg, 
wh
 of CN5102 on the LD-1010 board).
If iris blades work normally, confirm that they are closing completely 
and confirm following item.
・  Case of the iris blades do not close normally, replace the lens 
block).
・  Case of “E: 61: 30” is appeared and iris blades closed completely.
  Confirm that communication with lens block is normal.
・  Case of EVF is not displayed normally, check that connection between 
CN6702 on the CM-123 board (MAIN/SUB) and CN1011 or CN1014 
on the VC-1016 board by the FP-2134 or FP-2135 flexible board.
・  Case of EVF is displayed normally, replace the lens block.
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Inspect PITCH angular velocity sensors (SE7501 on the MS-1012 
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Inspect YAW angular velocity sensors (SE7501 on the MS-1012 board) 
peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to “1-6-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred”.
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Inspect the steadyshot circuit (IC5501 on the VC-1016 board).
E
6
2
0
4
Image vibration correction during 
handshake function does not work.
Inspect the image vibration angular velocity sensors (SE7701 on the 
LD-1009 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block. (Note 3) If an error occurs again, replace 
the VC-1016 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to “1-6-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred”.
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to “1-6-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred”.
E
6
2
2
0
Abnormality of thermistor.
Refer to “1-6-4. E : 62 : 20 (Abnormality of Thermistor) Occurred”.
E
9
1
0
1
Abnormality when flash is being charged.
Turn power off and turn power on again.
E
9
1
0
2
Abnormality of flash unit.
Turn power off and turn power on again.
E
9
1
0
3
Abnormality of flash unit Temperature 
detection.
Turn power off and turn power on again.
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each 
output of DC/DC converter (IC4301 on the VC-1016 board) with 
the AC adaptor connected DC JACK (J901). 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing or back up the 
flash memory
Check the OneNAND of CPU (IC1301, IC1601 on the VC-1016 
board).
E
9
4
0
1
Internal flash memory fault
Turn power off and turn power on again.
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-1016 board).
E
9
5
0
0
GPS hardware error
DEV-50V: Check whether the flexible flat cable of the GPS module is 
broken, and check whether it is inserted imperfectly. If there is no prob-
lem the flexible flat cable, inspect or replacement of the GPS module.
E
9
6
0
0
Map area mount error
DEV-50V: Inspect or replacement of the VC-1016 board.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
*
*
*
*
*
*
– ENGLISH –
1-6.  METHOD OF COPING WITH SHIFT LENS ERROR
VC-1016 BOARD (SIDE B)
C5525
C5526
C5527
C5528
C5529
R5506
C5530
C5531
IC5501
C5532
C5525
C5526
C5527
C5528
C5529
R5506
C5530
C5531
IC5501
C5532
Fig. 1
Measurement points on the VC-1016 board
about 330 msec
Note: The length of low section will vary a little depending on the conditions.
Fig. 2
Change in output voltage of R5506 on the VC-1016 board
1-6-1. E : 62 : 02 [Abnormality of IC for Steadyshot] Occurred
Order
Procedure
1
Turn the power OFF.
2
While measuring with an oscilloscope the output voltage of R5506 in the periphery of IC5501 on the VC-1016 board, turn the 
power ON to check that the output voltage immediately after the power on change as shown in Fig. 2.
3
If the output voltage change as shown in Fig. 2, replace the lens block (Note). If it does not change as shown in Fig. 2, inspect 
the camera control circuit (IC1301 of VC-1016 board) periphery.
Note:  When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Page of 27
Display

Click on the first or last page to see other DEV-30 / DEV-50 / DEV-50V (serv.man2) service manuals if exist.