DCR-VX2000, DCR-VX2000E (serv.man2) - Sony Movie Service Manual (repair manual). Page 3

Read Sony DCR-VX2000 / DCR-VX2000E (serv.man2) Service Manual online

— 3 —
Lens de
vice
Prism assy
(Including 3 CCD imagers)
V
AP unit
Mechanism deck
EVF block
LCD902 (LCD panel)
LCD block
LCD901 (LCD panel)
LCD block
ND901 (Fluorescent tube)
LCD block
In
v
erter unit
Control switch
(CF-4980)
Mechanism deck   M901 (Drum motor)
Mechanism deck   M902 (Capstan motor)
FP-594 board
H902 (T reel FG sensor)
SE-108 board
SE600 to 603 (PITCH/Y
A
W
 sensor)
PD-126 board
IC2101 (RGB dri
v
er (LCD))
PD-126 board
IC2103 (T
iming g
enera
tor (LCD))
LB-065 board
ND200 (Fluorescent tube (EVF))
VC-242 board
IC1802 (RGB dri
v
er (EVF))
VC-242 board
IC1803 (T
iming gener
a
tor (EVF))
VC-242 board
IC705, X701 (T
iming g
ener
a
tor)
VC-242 board
IC704 (S/H, 
A
GC)
VC-242 board
IC706 (A/D con
verter)
VC-242 board
IC802 (Camera micro processor)
VC-242 board
IC1301 (LINE IN/OUT amp)
VC-242 board
IC301 (D
V signal process)
VC-242 board
IC101 (EQ, 
A/D CONV
.,
 PLL)
VC-242 board
IC102 (REC/PB amp)
VC-242 board
IC803 (EVR)
Replaced parts
Block replacement
Parts replacement
z z
z
z z
z z
z z
z
z z
z z
z z
z z
z
z z
z z
z z
z z
Adjustment
Section
Camera
Adjustment
27MHz origin oscillation adj.
Zoom key center adj.
HALL adj.
Offset adj.
Flange back adj.
Pre-white balance data input
AWB standard data input
MAX GAIN adj.
LV standard data input
White balance ND filter 1 compensation
z
z
z
z
z
z
z
z
SECTION 5.
ADJUSTMENTS
Page
Before change
After change
5-21
1-3.
CAMERA SYSTEM ADJUSTMENTS
9. Pre White Balance Data Input
1-1. Adjusting items when replacing main parts and boards. (Refer to page 5-2)
• Adjusting items when replacing main parts
When replacing main parts, adjust the items indicated by z in the following table.
 : Added portion.
 : Changed portion.
 : Deleted portion.
Table. 5-1-1(1).
Processing after Completing Adjustments
Order Page Address Data
Procedure
3
0
01
00
Set the data.
4
Perform “Auto White Balance
Standard Data Input”.
Adjusting method:
Order Page Address Data
Procedure
7
6
01
7F
Set the data, and press PAUSE
button.
8
6
01
7D
Set the data, and press PAUSE
button. (Note)
9
6
02
Check that the data changes to
“01”.
Adjusting method:
Order Page Address Data
Procedure
7
F
16
Set the following data, and
press PAUSE button.
03 (NTSC), 83 (PAL)
8
6
01
7F
Set the data, and press PAUSE
button.
9
6
01
7D
Set the data, and press PAUSE
button. (Note)
10
6
02
Check that the data changes to
“01”.
Processing after Completing Adjustments
Order Page Address Data
Procedure
3
F
16
Set the following data, and
press PAUSE button.
13 (NTSC), 93 (PAL)
4
0
01
00
Set the data.
5
Perform “Auto White Balance
Standard Data Input”.
Page of 6
Display