SERVICE MANUAL
SUPPLEMENT-1
File this supplement-1 with the Service Manual.
    (PV00-019)
DCR-VX2000/VX2000E
RMT-811
Level 2
Subject:
• Change of Self-Diagnosis code table
• Change of Adjusting item
• Change of Adjustments
• Added of Supplied part
2000. 11
— 2 —
SELF-DIAGNOSIS FUNCTION
4.
SELF-DIAGNOSIS CODE TABLE 
(Refer to page 8)
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
E
Detailed
Code
3
0
4
0
4
2
9
7
9
8
9
9
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
9
7
9
8
9
9
0
0
Symptom/State
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum operations.
Mechanical position fault.
Mechanical position fault.
Mechanical position fault.
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
Winding S reel fault when counting
the rest of tape.
T reel fault.
S reel fault.
T reel fault.
FG fault when starting capstan.
FG fault when starting drum
FG fault during normal drum
operations
Mechanical position fault.
Mechanical position fault.
Mechanical position fault.
Difficult to adjust focus
(Cannot initialize focus.)
Self-diagnosis Code
Repaired b
y
:
Correction
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Inspect the lens block focus reset sensor (Pin wg of LA-026 board)
when focusing is performed when the control dial is rotated in the
focus manual mode, and the focus motor drive circuit (IC140 of
LA-026 board) when the focusing is not performed.
 : Added portion.
 : Changed portion.
Block
Function
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
6
1
— 3 —
Lens de
vice
Prism assy
(Including 3 CCD imagers)
V
AP unit
Mechanism deck
EVF block
LCD902 (LCD panel)
LCD block
LCD901 (LCD panel)
LCD block
ND901 (Fluorescent tube)
LCD block
In
v
erter unit
Control switch
(CF-4980)
Mechanism deck   M901 (Drum motor)
Mechanism deck   M902 (Capstan motor)
FP-594 board
H902 (T reel FG sensor)
SE-108 board
SE600 to 603 (PITCH/Y
A
W
 sensor)
PD-126 board
IC2101 (RGB dri
v
er (LCD))
PD-126 board
IC2103 (T
iming g
enera
tor (LCD))
LB-065 board
ND200 (Fluorescent tube (EVF))
VC-242 board
IC1802 (RGB dri
v
er (EVF))
VC-242 board
IC1803 (T
iming gener
a
tor (EVF))
VC-242 board
IC705, X701 (T
iming g
ener
a
tor)
VC-242 board
IC704 (S/H, 
A
GC)
VC-242 board
IC706 (A/D con
verter)
VC-242 board
IC802 (Camera micro processor)
VC-242 board
IC1301 (LINE IN/OUT amp)
VC-242 board
IC301 (D
V signal process)
VC-242 board
IC101 (EQ, 
A/D CONV
.,
 PLL)
VC-242 board
IC102 (REC/PB amp)
VC-242 board
IC803 (EVR)
Replaced parts
Block replacement
Parts replacement
z z
z
z z
z z
z z
z
z z
z z
z z
z z
z
z z
z z
z z
z z
Adjustment
Section
Camera
Adjustment
27MHz origin oscillation adj.
Zoom key center adj.
HALL adj.
Offset adj.
Flange back adj.
Pre-white balance data input
AWB standard data input
MAX GAIN adj.
LV standard data input
White balance ND filter 1 compensation
z
z
z
z
z
z
z
z
SECTION 5.
ADJUSTMENTS
Page
Before change
After change
5-21
1-3.
CAMERA SYSTEM ADJUSTMENTS
9. Pre White Balance Data Input
1-1. Adjusting items when replacing main parts and boards. (Refer to page 5-2)
• Adjusting items when replacing main parts
When replacing main parts, adjust the items indicated by z in the following table.
 : Added portion.
 : Changed portion.
 : Deleted portion.
Table. 5-1-1(1).
Processing after Completing Adjustments
Order Page Address Data
Procedure
3
0
01
00
Set the data.
4
Perform “Auto White Balance
Standard Data Input”.
Adjusting method:
Order Page Address Data
Procedure
7
6
01
7F
Set the data, and press PAUSE
button.
8
6
01
7D
Set the data, and press PAUSE
button. (Note)
9
6
02
Check that the data changes to
“01”.
Adjusting method:
Order Page Address Data
Procedure
7
F
16
Set the following data, and
press PAUSE button.
03 (NTSC), 83 (PAL)
8
6
01
7F
Set the data, and press PAUSE
button.
9
6
01
7D
Set the data, and press PAUSE
button. (Note)
10
6
02
Check that the data changes to
“01”.
Processing after Completing Adjustments
Order Page Address Data
Procedure
3
F
16
Set the following data, and
press PAUSE button.
13 (NTSC), 93 (PAL)
4
0
01
00
Set the data.
5
Perform “Auto White Balance
Standard Data Input”.
— 4 —
SECTION 5.
ADJUSTMENTS
Page
Before change
After change
5-26
 : Added portion.   
 : Changed portion.
1-3.
CAMERA SYSTEM ADJUSTMENTS
19. White Balance Check
R-Y
B-Y
1.5mm
1.0mm
6mm
6mm
Fig. 5-1-12. (B)
Fig. 5-1-12. (B)
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENT
2-2. Serial No. Input
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Read the serial No. on the name plate, and take it as D
1
.
Example: If the serial No. is 77881.
D
1
=77881
3)
Obtain D
2
 and H
1
 corresponding to D
1
 from Table 5-3-2.
Example: If D
1
 is “77881”.
D
2
=D
1
–65536=12345
H
1
=FE
5-42
Checking method:
Order Page Address Data
Procedure
13
F
11
04
Set the data, and press PAUSE
button.
14
1
Check that the second digit of
the display data (Note) is an odd
number.
Specified value:
     1 : XX : XX
Odd number
15
6
04
C6
Set the data.
R-Y
B-Y
1.0mm
1.0mm
6mm
6mm
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Read the serial No. on the name plate, and take it as D
1
.
Example: If the serial No. is 77881.
D
1
=77881
Note:
Use six digits of the low rank when a serial No. is more
than seven digits.
3)
Obtain D
2
 and H
1
 corresponding to D
1
 from Table 5-3-2.
Example: If D
1
 is “77881”.
D
2
=D
1
–65536=12345
H
1
=FE
Checking method:
Order Page Address Data
Procedure
13
F
11
04
Set the data, and press PAUSE
button.
14
1
Check that the second digit of
the display data (Note) is “1”.
Specified value:
     1 : XX : XX
1
15
6
04
06
Set the data.
Page of 6
Display

Download Sony DCR-VX2000 / DCR-VX2000E (serv.man2) Service Manual (Repair Manual)

Here you can read online and download Sony DCR-VX2000 / DCR-VX2000E (serv.man2) Service Manual in PDF. DCR-VX2000 / DCR-VX2000E (serv.man2) service manual will guide through the process and help you recover, restore, fix, disassemble and repair Sony DCR-VX2000 / DCR-VX2000E (serv.man2) Movie. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.