DCR-TRV890E, DCR-TRV900, DCR-TRV900E - Sony Movie Service Manual (repair manual). Page 118

Read Sony DCR-TRV890E / DCR-TRV900 / DCR-TRV900E Service Manual online

5-15
9. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color bar standard picture frame)
(95cm from the front of the lens)
Adjustment Page
F
Adjustment Address
2C
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 96, and set data: 00.
3)
Select page: 6, address: 97, and set data: 2C.
4)
Select page: 6, address: 01, set data: 6F and press the PAUSE
button of the adjustment remote commander.
(When the adjustment data is take in, the data will be
automatically input to page: F, address: 2C.)
5)
Select page: 6, address: 02, and check that the data is changed
to “01”.
Processing after Completing Adjustments
1)
Select page: 6, address: 96, and set data: 00.
2)
Select page: 6, address: 97, and set data: 00.
3)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
10. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
3E, 3F
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, and set data: 0D, and press the
PAUSE button of the adjustment remote commander.
(When the adjustment data is take in, the data will be
automatically input to page: F, address: 3E and 3F.)
Processing after Completing Adjustments
1)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
Page of 127