5-14
7. Pre White Balance Data Input
At 3200k, input the pre white balance standard data.
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
E
Adjustment Address
2A, 2B
Switch setting:
1)
ND filter ........................................................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 1C, and set data: 02.
3)
Select page: F, address: 20, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
4)
Select page: F, address: 21, set data: 28, and press the PAUSE
button.
5)
Select page: F, address: 22, set data: 00, and press the PAUSE
button.
6)
Select page: F, address: 23, set data: 50, and press the PAUSE
button.
7)
Select page: 6, address: 01, set data: 7F, and press the PAUSE
button.
8)
Select page: 6, address: 01, and set data: 7D, press the PAUSE
button.
(When the standard data is take in, the data will be automatically
input to page: E, address: 2A and 2B.)
9)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments
1)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
2)
Select page: 6, address: 1C, and set data: 00.
3)
Select page: 0, address: 01, and set data: 00.
4)
Perform “Auto White Balance Standard Data Input”.
8. Auto White Balance Standard Data Input
At 3200K, input the white balance standard data.
Subject
Clear chart
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
20 to 23
Note 1:
 Perform “Pre White Balance Data Input” before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is 00. If not, turn the
power of the unit OFF/ON.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, and set data: 11, and press the
PAUSE button of the adjustment remote commander.
3)
Select page: 6, address: 01, and set data: 0B, and press the
PAUSE button.
(When the standard data is take in, the data will be automatically
input to page: F, address: 20 to 23.)
4)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments
1)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
Page of 127