DCR-TRV360, DCR-TRV361, DCR-TRV460, DCR-TRV460E, DCR-TRV461E (serv.man4) - Sony Movie Service Manual (repair manual). Page 58

Read Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) Service Manual online

DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-55
4-3.
SERVICE MODE
Additional note on adjustment
Note 1:
If reading/writing data on page 18, 1C, set data: 01 to
page: 0, address: 10, and then select page 8, C. By this
data setting, the page 18, 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
After the completion of the all adjustments, cancel the
service mode by either of the following ways.
1) After data on page: A, 18, 1C is restored, press the
RESET button and unplug the main power supply.
(In this case, date and time and menu setting have
been set by users are canceled. Perform resetting)
2) After data on page: A, 18, 1C is restored, select page:
0, address: 01, and return the data to 00. And when
data on page: 7 is changed, return data to the original
condition.
1. Setting the Test Mode
Page 18
Address 12
Data
Function
00
Normal
01
Test mode (Hi8/Standard8 mode)
Various emergency prohibitions and releases
Drum emergency, capstan emergency, loading motor
emergency, reel emergency, tape top and end, DEW
detection
Page 1C
Address 09
Data
Function
FF
Normal
00
Test mode (Digital8 mode)
Various emergency prohibitions and releases
Drum emergency, capstan emergency, loading motor
emergency, reel emergency, tape top and end, DEW
detection
Page A
Address 10
Data
Function
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
03
Forced camera + VTR power ON
05
Forced memory power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page A, 18, 1C the data set will be recorded in the non-
volatile memory by pressing the PAUSE button of the adjust-
ment remote commander. In this case, take note that the test
mode will not be exited even when the main power is turned off
(8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjust-
ment remote commander. And select page: 0, address: 01, and
set data: 00.
2. Emergence Memory Address
2-1. C Page Emergence Memory Address
Page C
Address F4 to FF
Address
Contents
F4
EMG code when first error occurs
F6
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
F7
Lower: MSW code to be moved when first error
occurs
F8
EMG code when second error occurs
FA
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
FB
Lower: MSW code to be moved when second error
occurs
FC
EMG code when last error occurs
FE
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
FF
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data “00” is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (F4 to F7). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note:
After completing adjustments, be sure to initialize the data
of addresses F4 to FF to “00”.
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
3
01
37
Press PAUSE button.
3
3
02
Check the data changes to
“00”.
4
0
01
00
Page of 66
Display

Click on the first or last page to see other DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) service manuals if exist.