DCR-TRV360, DCR-TRV361, DCR-TRV460, DCR-TRV460E, DCR-TRV461E (serv.man4) - Sony Movie Service Manual (repair manual). Page 53

Read Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) Service Manual online

DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-50
6.
Hi8/Standard8 AFC f
0
 Adjustment 
RadarW
RadarW
RadarW
(VC-345 Board) (DCR-TRV460/TRV460E/TRV461E)
Adjust the pull-in range of the clock generator (IC2201) for A/D
conversion during Hi8/Standard8 playback.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Displayed data of page: 3, address:
9D
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
34
Specified value
The data of page: 3, address: 9D is
“7C” to ”84”.
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
34
30
Press PAUSE button.
3
A
10
02
Press PAUSE button.
4
3
0D
04
Press PAUSE button.
5
3
93
04
6
3
9E
01
7
Wait for 1.5 second.
8
3
01
82
Press PAUSE button. (Note 3)
9
3
02
Check the data changes to
“00”.
10
3
03
Check the data is “00”.
11
3
9D
Check that the data satisfied
the specified value.
12
3
0D
00
Press PAUSE button.
13
3
93
00
14
3
9E
00
15
A
10
00
Press PAUSE button.
16
0
01
00
Note 2:
For the bit value, refer to “6-4. SERVICE MODE”, “4-3.
3. Bit Value Discrimination”.
Note 3:
The adjustment data will be automatically input to page:
C, address: 34.
Page of 66
Display

Click on the first or last page to see other DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) service manuals if exist.