1. SELF-DIAGNOSIS FUNCTION
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and
service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
function starts working, and displays on the LCD screen what to do.
This function consists of two display; self-diagnosis display and
service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
2. SELF-DIAGNOSIS DISPLAY
When problems occur while the unit is operating, the counter of the
LCD screen shows a 4-digit display consisting of an alphabet and
numbers, which blinks at 3.2 Hz. This 5-character display indicates
the “repaired by:”, “block” in which the problem occurred, and
“detailed code” of the problem.
LCD screen shows a 4-digit display consisting of an alphabet and
numbers, which blinks at 3.2 Hz. This 5-character display indicates
the “repaired by:”, “block” in which the problem occurred, and
“detailed code” of the problem.
[3]
C : 3 1 : 1 1
SELF-DIAGNOSIS FUNCTION
3-2. Switching of Backup No.
By rotating the control dial, past self-diagnosis codes will be shown in order. The backup No. in the [] indicates the order in which the problem
occurred. (If the number of problems which occurred is less than 6, only the number of problems which occurred will be shown.)
[1] : Occurred first time
occurred. (If the number of problems which occurred is less than 6, only the number of problems which occurred will be shown.)
[1] : Occurred first time
[4] : Occurred fourth time
[2] : Occurred second time
[5] : Occurred fifth time
[3] : Occurred third time
[6] : Occurred the last time
3-3. End of Display
Turning OFF the power supply will end the service mode display.
Note:
The self-diagnosis display data will be backed up by the coin-type lithium battery. When this coin-type lithium battery (LI-62 board) is
disconnected, the self-diagnosis data will be lost by initialization.
disconnected, the self-diagnosis data will be lost by initialization.
1 1
3 1
C
LCD screen
Blinks at 3.2 Hz
Lights up
Backup No.
LCD screen
self-diagnosis codes
Order of previous errors
3. SERVICE MODE DISPLAY
The service mode display shows up to six self-diagnosis codes shown in the past.
3-1. Display Method
While pressing the “FADER” key, set the switch from OFF to “VTR or PLAYER”, and continue pressing the “FADER” key for 5 seconds
continuously. The service mode will be displayed, and the counter will show the backup No. and the 5-character self-diagnosis codes.
continuously. The service mode will be displayed, and the counter will show the backup No. and the 5-character self-diagnosis codes.
Repaired by:
Block
Detailed Code
Refer to page 6
Self-diagnosis Code Table.
Self-diagnosis Code Table.
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service engineer
H : Corrected by dealer
E : Corrected by service engineer
Indicates the appropriate
step to be taken.
E.g.
31 .... Reload the tape.
32 .... Turn on power again.
step to be taken.
E.g.
31 .... Reload the tape.
32 .... Turn on power again.
C : 3 1 : 1 1
[3] C : 3 1 : 1 1
Control dial