DCR-SC100, DCR-SC100E - Sony Movie Service Manual (repair manual). Page 4

Read Sony DCR-SC100 / DCR-SC100E Service Manual online

— 4 —
SERVICE NOTE
Battery terminal 
Battery switch
Battery terminal 
Battery SIG terminal
1. POWER SUPPLY DURING REPAIRS
In this unit, about 25 seconds after power is supplied (8.4V) to the
battery terminal using the service power cord (J-6082-223-A), the
power is shut off so that the unit cannot operate.
This following two methods are available to prevent this. Take note
of which to use during repairs.
Method 1.
Connect the servicing remote commander RM-95 (J-6082-053-B) to
the LANC jack, and set the remote commander switch to the “ADJ”
side.
Method 2.
Press the following battery switch using adhesive tape, etc.
2. HANDLING THE VC. MR BOARD
Never heat the VC and MR boards with hot air. (Malfunctions may
result.)
Also remove after dehumidifying.
3. SPECIAL PRECAUTIONS ON DISCONNECTION
OF CONNECTOR ATTACHED TO THE FLEXIBLE
BOARD
Apply force in the arrow direction and disconnect.
Do not apply force in the     direction as this will cause the solder
(of the pin) to float easily.
When touching the pins with the solder iron, do not touch other
parts. (deformation may occur.)
Ensure no folding lines are formed on the flexible board.
(This will cause the internal copper film to cut easily.)
Flexible board
Connector
*
*
*
Page of 121