DCR-PC53E, DCR-PC55, DCR-PC55E (serv.man4) - Sony Movie Service Manual (repair manual). Page 43

Read Sony DCR-PC53E / DCR-PC55 / DCR-PC55E (serv.man4) Service Manual online

6-41
DCR-PC53E/PC55/PC55E
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Initialization of 8, A, B, C, D, E, F, 18, 19, 1A, 1B, 1C, 1E,
1F Page Data
If the 8, A, B, C, D, E, F, 18, 19, 1A, 1B, 1C, 1E, 1F page data is
erased due to some reason, perform “1-2. INITIALIZATION OF 8,
A, B, C, D, E, F, 18, 19, 1A, 1B, 1C, 1E, 1F PAGE DATA” of “6-1.
CAMERA SECTION ADJUSTMENT”
Note: When reading or writing the 18, 19, 1A, 1B, 1C, 1E, 1F page data,
select page: 0, address: 10, and set data: 01, then select 8, 9, A, B, C,
E or F page. The 18, 19, 1A, 1B, 1C, 1E  or 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.3.
Serial No. Input
2. Serial No. Input
2-1. Company ID Input
Write the company ID in the EEPROM (nonvolatile memory).
Page
C
Address
E0, E1, E2, E3, E4
Note: The data of page: 0, address: 10 must be “00”.
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: C, addresses: E0 to E4.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
6)
Obtain the hexadecimal corresponding to D
3
 from Table 6-3-
3, and take this as H
3
.
Example: If D
3
 is “12288”.
H
= 3000
7)
Obtain the difference D
4
 between D
2
 and D
3
.
(Decimal calculation, 0   D
4
   255)
D
= D
2
 – D
3
Example: If D
2
 is “12345” and D
3
 is “12288”.
D
4
 =
 
12345 – 12288 = 57
8)
Convert D
4
 to hexadecimal, and take this as H
4
.
(Refer to “Hexadecimal-decimal conversion table” in “6-4.
Service Mode”.)
Example: If D
4
 is “57”.
H
=
 
39
9)
Input the upper 2 digits of H
3
 to page: C, address: E6.
Example: If H
3
 is “3000”.
Select page: C, address: E6, set data: 30, and
press the PAUSE button.
10) Input H
4
 to page: C, address: E7.
Example: If H
4
 is “39”.
Select page: C, address: E7, set data: 39, and
press the PAUSE button.
11) Select page: 0, address: 01, and set data: 00.
Address
E0
E1
E2
E3
E4
Data
08
00
46
01
02
3)
Select page: 0, address: 01, and set data: 00.
2-2. Serial No. Input
Write the serial No. and model code in the EEPROM (nonvolatile
memory). Convert the serial No. on the name plate from decimal to
hexadecimal, and write in the EEPROM.
Page
C
Address
E5, E6, E7
Note: The data of page: 0, address: 10 must be “00”.
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Read the serial No. on the name plate, and take it as D
1
.
Example: If the serial No. is 77881.
D
= 77881
Note: Use six digits of the low rank when a serial No. is more than
seven digits.
3)
Obtain D
2
 and H
1
 corresponding to D
1
 from Table 6-3-2.
Example: If D
1
 is “77881”.
D
= D
– 65536 = 12345
H
= FE
4)
Input H
1
 to page: C, address: E5. (Model code input)
Example: If H
1
 is “FE”.
Select page: C, address: E5, set data: FE,
and press the PAUSE button.
5)
Obtain the maximum decimal not exceeding D
2
 from Table 6-
3-3, and take this as D
3
.
Example: If D
2
 is “12345”.
D
= 12288
D
1
 (Decimal)
000001 to 065535
065536 to 131071
131072 to 196607
196608 to 262143
262144 to 327679
327680 to 393215
393216 to 458751
458752 to 524287
524288 to 589823
589824 to 655359
655360 to 720895
720896 to 786431
786432 to 851967
851968 to 917503
917504 to 983039
983040 to 999999
D
2
 (Decimal)
D
1
D
1
 – 65536
D
1
 – 131072
D
1
 – 196608
D
1
 – 262144
D
1
 – 327680
D
1
 – 393216
D
1
 – 458752
D
1
 – 524288
D
1
 – 589824
D
1
 – 655360
D
1
 – 720896
D
1
 – 786432
D
1
 – 851968
D
1
 – 917504
D
1
 – 983040
H
1
 (Hexadecimal)
(Service model code)
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
Table 6-3-2.
Page of 61
Display

Click on the first or last page to see other DCR-PC53E / DCR-PC55 / DCR-PC55E (serv.man4) service manuals if exist.