DCR-PC53E, DCR-PC55, DCR-PC55E (serv.man4) - Sony Movie Service Manual (repair manual). Page 47

Read Sony DCR-PC53E / DCR-PC55 / DCR-PC55E (serv.man4) Service Manual online

6-45
DCR-PC53E/PC55/PC55E
3-4.
VIDEO SYSTEM ADJUSTMENTS
Note1: Before perform the servo and RF system adjustments, check that
the specified value of “36 MHz Origin Oscillation Check” of
“CAMERA SYSTEM ADJUSTMENT” is satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
Note2: NTSC model : DCR-PC55
PAL model
: DCR-PC53E/PC55E
1. S VIDEO OUT Y Level Adjustment (VC-379 board)
Mode
CAMERA–TAPE
Subject
Arbitrary
Measurement Point
Y signal terminal of S VIDEO plug of
A/V jack (75
 terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
25
Specified Value
A = 1000 
±
 14mV
Note: The data of page: 0, address: 10 must be “00”.
Switch setting:
DEMO MODE (Menu setting) ................................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
8
4C
94
Set the data, and press PAUSE
button.
3
3
0C
02
Set the data, and press PAUSE
button.
4
C
25
Change the data and set the Y
signal level (A) to the specified
value.
5
C
25
Press PAUSE button.
6
3
0C
00
Set the data, and press PAUSE
button.
7
8
4C
96
Set the data, and press PAUSE
button.
8
0
01
00
Set the data.
2. S VIDEO OUT Chroma Level Adjustment (VC-379 board)
Mode
CAMERA-TAPE
Subject
Arbitrary
Measurement Point
Chroma signal terminal of S VIDEO
plug of A/V jack (75
 terminated)
External trigger: Y signal terminal of
S VIDEO plug of A/V jack
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
26, 27
Specified Value
Cr level
: A = 714 
±
 14mV (NTSC)
A = 700 
±
 14mV (PAL)
Cb level
: B = 714 
±
 14mV (NTSC)
B = 700 
±
 14mV (PAL)
Burst level : C = 286 
±
 6mV (NTSC)
C = 300 
±
 6mV (PAL)
Note: The data of page: 0, address: 10 must be “00”.
Switch setting:
DEMO MODE (Menu setting) ................................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
8
4C
94
Set the data, and press PAUSE
button.
3
3
0C
02
Set the data, and press PAUSE
button.
4
C
26
Change the data and set the Cr signal
level (A) to the specified value.
5
C
26
Press PAUSE button.
6
C
27
Change the data and set the Cb signal
level (B) to the specified value.
7
C
27
Press PAUSE button.
8
Check that the burst signal level
(C) is satisfied the specified value.
9
3
0C
00
Set the data, and press PAUSE
button.
10
8
4C
96
Set the data, and press PAUSE
button.
11
0
01
00
Set the data.
Fig. 6-3-4.
Fig. 6-3-5.
H
A
H
C
A
0.28 
µ
sec (NTSC)
0.23 
µ
sec (PAL)
B
0.28 
µ
sec (NTSC) 
0.23 
µ
sec (PAL)
Page of 61