5-15
DCR-IP5/IP5E/IP7BT/IP7E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENT” are
satisfied.
Note:
NTSC model: DCR-IP5/IP7BT
PAL model: DCR-IP5E/IP7E
1. 48MHz Origin Oscillation Adjustment
(VC-263 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
R1125 (Pin 4 of IC1103)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
12
Specified Value
f = 27000000 ± 90Hz
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
12
Change the data and set the fre-
quency (f) to the specified value.
3
F
12
Press PAUSE button.
4
0
01
00
Set the data.
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
16, 17, 18, 19, 1A, 1B, 1C
Specified Value 1
15 to 19
Specified Value 2
88 to 8C
Specified Value 3
15 to 19
Specified Value 4
88 to 8C
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
17
Set the data.
3
6
95
8A
Set the data.
4
6
01
6D
Set the data, and press PAUSE button.
5
6
02
Check that the data changes to
“01”. (Note2)
6
6
01
00
Set the data, and press PAUSE button.
Note2:
The adjustment data will be automatically input to page: F, address:
16 to 1C.
Checking method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
39
Set the data, and press PAUSE button.
3
6
01
01
Set the data, and press PAUSE button.
4
1
Check that the IRIS display data
(Note1) satisfies the specified value 1.
5
6
01
03
Set the data, and press PAUSE button.
6
1
Check that the IRIS display data
(Note1) satisfies the specified value.2.
7
F
10
43
Set the data, and press PAUSE button.
8
6
01
69
Set the data, and press PAUSE button.
9
1
Check that the ND display data (Note1)
satisfies the specified value 3.
10
6
01
6B
Set the data, and press PAUSE button.
11
1
Check that the ND display data (Note1)
satisfies the specified value.4.
12
F
10
00
Set the data, and press PAUSE button.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE button.
4
6
04
00
Set the data.
5
0
01
00
Set the data.
Fig. 5-1-6.
IC1103
VC-263 board
R1125
Page of 63