Read Sharp XL-1000 (serv.man14) Technical Bulletin online
AUD2002 12 03
Month of Issue:
January 2003
Classification:
White
AUDIO TECHNICAL BULLETIN
Page 1 of 1
Sharp Electronics (UK) Limited
Reference TT23122002
Revision 1
White – Carry out as required
Yellow – Carry out as required and whenever the unit comes in for service
Red – Carry out on all units
MODELS
XL1000H
XL3000H
SYMPTOM Dead. No operation and no display.
CAUSE
C705 short circuit
ACTION
Replace C705 using the part number given below.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
C705
Capacitor, 1nF 16V
VCKYPA1HF103Z
AB
Display