DCR-IP5, DCR-IP5E, DCR-IP7BT, DCR-IP7E (serv.man3) - Sony Movie Service Manual (repair manual). Page 20

Read Sony DCR-IP5 / DCR-IP5E / DCR-IP7BT / DCR-IP7E (serv.man3) Service Manual online

5-18
DCR-IP5/IP5E/IP7BT/IP7E
5. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
5-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection glass)
(Luminance: 350 ± 30 lux)
Measurement Point
Display data of page: F, address: 63,
65
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
4A to 4F, 5A to 5E, 60 to 63, 65
Specified Value
Data of address 63: 00 to 0E
Upper digit of address 65 data: 0 to A
Lower digit of address 65 data: 0 to A
Note1:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note2:
This adjustment should be carried out upon completion of the
following adjustments.
HALL adjustment, MR adjustment
Switch setting:
POWER .................................................................. CAMERA
Preparations:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
3
6
01
15
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note3)
5
F
63
Check that the data is “00” to
“0E”.
6
F
65
Check that the upper digit of the
data is “0” to “A”.
7
F
65
Check that the lower digit of the
data is “0” to “A”.
Note3:
The adjustment data will be automatically input to page: F, address::
4A to 4F, 5A to 5E, 60 to 63, 65.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
Turn off the power and turn on again.
3
Perform “Flange Back Adjustment (2)”
5-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
4A to 4F, 5A to 5E, 60 to 63, 65
Switch setting:
POWER .................................................................. CAMERA
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
Place a ND filter on the lens so
that the optimum image is obtain.
3
6
01
29
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note)
Note:
The adjustment data will be automatically input to page: F, address::
4A to 4F, 5A to 5E, 60 to 63, 65.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Perform “Flange Back Check”.
Page of 63