DCR-IP1, DCR-IP1E (serv.man4) - Sony Movie Service Manual (repair manual). Page 58

Read Sony DCR-IP1 / DCR-IP1E (serv.man4) Service Manual online

DCR-IP1/IP1E
6-55
4-3.
SERVICE MODE
Additional note on adjustment
Note:
Before performing the adjustment, check that the data of
page: 0, address: 10 is “00” .
If not, select page: 0, address: 10, and set data“00” .
1.
Setting the Test Mode
Page D
Address 10
Data
Function
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
03
Forced camera + VTR power ON
05
Forced memory power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page D, the data set will be recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment re-
mote commander. In this case, take note that the test mode will
not be exited even when the main power is turned off (8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjust-
ment remote commander. And select page: 0, address: 01, and
set data: 00.
2.
Emergence Memory Address
2-1.
C Page Emergence Memory Address
Page C
Address 20 to 2B
Address
Contents
20
EMG code when first error occurs
22
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
23
Lower: MSW code to be moved when first error
occurs
24
EMG code when second error occurs
26
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
27
Lower: MSW code to be moved when second error
occurs
28
EMG code when last error occurs
2A
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
2B
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data “00” is written in the above
addresses (20 to 2B). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (20 to 23). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (24 to 27).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (28 to 2B).
Note:
After completing adjustments, be sure to initialize the data
of addresses 20 to 2B to “00”.
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
3
F6
01
Press PAUSE button.
3
3
F6
Check the data Changes to
“00”.
4
0
01
00
Page of 66