CCD-TRV128, CCD-TRV228, CCD-TRV228E, CCD-TRV328, CCD-TRV428, CCD-TRV428E (serv.man2) - Sony Movie Service Manual (repair manual). Page 13

Read Sony CCD-TRV128 / CCD-TRV228 / CCD-TRV228E / CCD-TRV328 / CCD-TRV428 / CCD-TRV428E (serv.man2) Service Manual online

CCD-TRV128/TRV228/TRV228E/TRV328/TRV428/TRV428E
6-11
8. F Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, A, C, D, E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, A, C, D, E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10
80
80
28 MHz origin osillation adj.
11
Fixed data-1 (Initialized data)
12
4A
4A
Hall adj.
13
56
56
14
11
11
15
20
20
16
02
02
17
E0
E0
18, 19
Fixed data-1 (Initialized data)
1A
00
00
LV standard data input
1B
60
60
1C to 29
Fixed data-1 (Initialized data)
2A
1B
1B
Auto white balance
2B
00
00
standard data input
2C
07
07
2D
00
00
2E
0E
0E
Auto white balance adj.
2F
00
00
30
0D
0D
31
00
00
32
Fixed data-1 (Initialized data)
33
22
22
Color reproduction adj.
34
Fixed data-1 (Initialized data)
35
27
24
Color reproduction adj.
36 to 39
Fixed data-1 (Initialized data)
3A
00
00
Color reproduction adj.
3B
F1
EF
3C, 3D
Fixed data-1 (Initialized data)
3E
29
2A
Auto white balance adj.
3F
80
C0
40
58
5A
41
C0
C0
42, 43
Fixed data-1 (Initialized data)
44
28
28
Flange back adj.
45
EC
EC
46
35
35
47
8F
8F
48
13
13
49
B8
B8
4A
00
00
4B
00
00
4C
00
00
4D
00
00
4E
2B
2B
Address
Initial value
Remark
NTSC PAL
4F
19
19
Flange back adj.
50
00
00
51
32
32
52
04
04
53
00
00
54
00
00
55 to 57
Fixed data-1 (Initialized data)
58
59
Fixed data-2
5A
FF
FF
Optical axis adj.
5B to 8D
Fixed data-1 (Initialized data)
8E
8F
Fixed data-2
90
91 to 96
Fixed data-1 (Initialized data)
97
Fixed data-2
98 to A5
Fixed data-1 (Initialized data)
A6
Fixed data-2
A7 to AC
Fixed data-1 (Initialized data)
AD
AE
AF
Fixed data-2
B0
B1 to C4
Fixed data-1 (Initialized data)
C5
C6
Fixed data-2
C7 to E0
Fixed data-1 (Initialized data)
E1
Fixed data-2
E2 to EA
Fixed data-1 (Initialized data)
EB
Fixed data-2
EC to EE
Fixed data-1 (Initialized data)
EF
Fixed data-2
F0 to FF
Fixed data-1 (Initialized data)
9.
1F Page table
Note 1:
If reading/writing data on pages 1F, set data: 01 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, A, C, D, E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, A, C, D, E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 1D
Fixed data-1 (Initialized data)
1E
Fixed data-2
1F to FF
Fixed data-1 (Initialized data)
Page of 50