CCD-TRV128, CCD-TRV228, CCD-TRV228E, CCD-TRV328, CCD-TRV428, CCD-TRV428E (serv.man2) - Sony Movie Service Manual (repair manual). Page 17

Read Sony CCD-TRV128 / CCD-TRV228 / CCD-TRV228E / CCD-TRV328 / CCD-TRV428 / CCD-TRV428E (serv.man2) Service Manual online

CCD-TRV128/TRV228/TRV228E/TRV328/TRV428/TRV428E
6-15
4. Flange Back Check
Mode
CAMERA
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DISPLAY (Menu setting) ................................................ LCD
Note 2:
When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 2.0 m
from the front of the lens.
2
To open the IRIS, decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
3
6
40
01
4
6
41
01
5
Shoot the Siemens star with
the zoom TELE end.
6
Turn on the auto focus.
7
0
03
0F
8
1
Check that the lens is
focused. (Note 2)
9
6
21
10
10
Shoot the Siemens star with
the zoom WIDE end.
11
Observe the TV monitor and
check that the lens is
focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
0
03
00
Page of 50
Display

Click on the first or last page to see other CCD-TRV128 / CCD-TRV228 / CCD-TRV228E / CCD-TRV328 / CCD-TRV428 / CCD-TRV428E (serv.man2) service manuals if exist.