6-18
1-2-11. Picture frame setting
Subject
Color bar chart standard picture frame
(1.5m from the front of the lens)
Measurement Point
VIDEO output terminal
(Terminated in 75
)
Measuring Instrument
Oscilloscope and monitor TV
Specification Value
A=B, C=D, t=0 
±
 0.1msec
Note :
Set the STEADYSHOT (MENU display) to OFF and the D
ZOOM (MENU display) to OFF.
Setting procedure:
Order
Procedure
1
Set the data : 02 to page : 2, address : 40,
and press the PAUSE button.
2
Set the data : 01 to page : 2, address : 41,
and press the PAUSE button.
3
Turn OFF the auto focus.
4
Adjust the focus using the focus knob.
5
Adjust direction anD ZOOM of camera so that the
picture frame is adjusted as specified by Fig. 6-1-8
and Fig. 6-1-9.
6
Write down markings on the picture frame on
the monitor screen.  If the “color bar chart standard
picture frame” or “white pattern standard picture
frame” is specified in the following adjustment items,
obtain this picture frame.
Confirm with an oscilloscope
1. Horizontal rate
2. Vertical rate
Fig. 6-1-8
Confirm on TV monitor (underscanned display)
Fig. 6-1-9