6-10
1-2.
CAMERA SYSTEM ADJUSTMENTS
1-2-1. Adjustment points when major parts have been
replaced
When the CCD imager or lens block is replaced, adjust the items
indicated by 
® in the following table.
1-2-2. Preparation for adjustment
Note 1 :
Refer to “2 Removal” for details of how to remove the
cabinet and boards.
1)
Connect the adjusting equipment according to Fig. 6-1-5. (Page
6-3.)
2)
When the cabinet (R) assy is removed, the re-chargeable button
battery (FP-415 board) power supply will be disconnected as
well, and all the data such as data, time, user settings made will
be lost.
After completing adjustments, set these data again.
3)
Even if the rear cabinet control key board (CF block) and LCD
board (FP-412 board) have been removed, the power can be
turned ON by setting the forced camera power supply ON mode
(Note 2). Carry out camera operations using the adjustment
remote commander. To remove the control key board, disconnect
the following connector.
1.
VC-175 board CN011 (16P, 0.5mm)
2.
VC-175 board CN013 (6P, 0.5mm)
After completing adjustments, be sure to exit forced camera
power supply ON mode (Note 3).
HALL adjustment
Flange back adjustment
IRIS IN/OUT adjustment
MAX GAIN adjustment
Color reproduction
adjustment
Auto white balance
reference data input
Auto white balance
adjustment
When the CCD
imager is replaced
®
®
®
®
®
®
When the lens
block is replaced
®
®
®
Note 2 :
Setting the forced camera power supply ON mode
1) Set data: 01 to page : 0, address : 01.
2) Set data: 01 to page : D, address : 10, and press the
PAUSE button of the adjusting remote commander.
The camera power supply can be turned ON even if the cabinet (R)
has been removed using the above steps. After completing
adjustments, be sure to exit the forced power supply ON mode.
Note 3 :
Exiting the forced camera ON mode
1) Set data : 01 to page : 0, address : 01
2) Set data : 00 to page : D, address : 10, and press the
PAUSE button of the adjusting remote commander.
3) Set data : 00 to page : 0, address : 01.
Page of 127