CCD-TRV101, CCD-TRV101E - Sony Movie Service Manual (repair manual). Page 125

Read Sony CCD-TRV101 / CCD-TRV101E Service Manual online

6-16
1-2-9. Flange back adjustment
Purpose :
Automatic flange back adjustment of inner focus
lens.
Adjustment error :
Loss of focus when switched between auto focus
and manual focus.
Chart for flange back adjustment
Subject
(Placed 1982mm in front of the lens
with illumination of 300 
±
 50 lux.)
Measurement Point
Confirm the focus on monitor TV.
Measuring Instrument
Confirm the focus on monitor TV
Adjustment Page
F
Adjustment Address
2E to 33
49 to 4D
Note :
Set the STEADYSHOT (MENU display) to OFF and the D
ZOOM (MENU display) to OFF.
Adjustment procedure:
Processing after Adjustments:
Order
Page
Address
Data
Procedure
1
Check that the center of the flange back adjustment chart coincides with that of the display on
the monitor at both ends : TELE end and the WIDE end of the zoom lens.
2
0
01
01
Set the data.  (Preparation)
3
2E
CD
2F
19
30
92
31
21
32
12
F
33
14
Confirm data of each address.
49
41
4A
00
4B
19
4C
00
4D
2E
4
2
02
Confirm that the data is 00.
5
2
01
13
After setting the data, press the PAUSE button.
6
2
01
15
After setting the data, press the PAUSE button.
The adjustment data is automatically input to page : F, addresses : 2E to 33, 49 to 4D.
7
2
02
Confirm that the data is 01.
Fig.6-1-7.
Order
Page
Address
Data
Procedure
1
0
01
00
Set the data.
2
Turn the main power supply (7.2 V) OFF, then ON.
(If this step is not performed, the camera will be out of focus.)
Page of 127