Read Sony CCD-TR555 / CCD-TR555E Service Manual online
6-22
1-2-15. Auto white balance reference data input
Subject
Clear chart
(Color bar standard picture frame)
(Color bar standard picture frame)
Adjustment Page
F
Adjustment Address
2A to 2D
Note 1 :
Perform this adjustment after the “Color reproduction
adjustment”.
adjustment”.
Note 2 :
Confirm that the data is 00 at address : 02 on page : 2.
(If the data is “01”, turn off the main power of the unit then
back on.)
(If the data is “01”, turn off the main power of the unit then
back on.)
Adjustment procedure:
Processing after Adjustments:
Related Adjustments:
Auto white balance adjustment
Auto white balance adjustment
Order
Page
Address
Data
Procedure
1
2
01
00
After setting the data, press the PAUSE button.
2
0
01
00
Set the data. (End)
Order
Page
Address
Data
Procedure
1
Turn OFF the ND filter.
2
Turn OFF the main power of the unit then back ON.
3
Shoot a Clear chart with the standard picture frame.
4
0
01
01
Set the data. (Preparation)
5
Wait for two seconds.
6
2
01
11
After setting the data, press the PAUSE button.
7
2
01
0D
After setting the data, press the PAUSE button.
(The data is input automatically to the address : 2A to 2D.)
(The data is input automatically to the address : 2A to 2D.)
8
Turn ON the ND filter.
9
2
01
11
After setting the data, press the PAUSE button.
10
2
01
0D
After setting the data, press the PAUSE button.
(The data is input automatically to the address : 2A to 2D.)
(The data is input automatically to the address : 2A to 2D.)
11
2
02
Confirm that the data is 01.
12
Perform the “Auto white balance adjustment”.