CCD-TR555, CCD-TR555E - Sony Movie Service Manual (repair manual). Page 113

Read Sony CCD-TR555 / CCD-TR555E Service Manual online

6-17
1-2-10. Flange back check
Siemens star
Subject
(Placed 2000mm in front of the lens
with illumination of about 200 lux.)
Measurement Point
Confirm focus on monitor TV
Measuring Instrument
Specification Value
Picture must have good focus at both
TELE and WIDE ends.
Note :
It is judged from the page 1 display on the adjustment remote
commander if the picture has good focus while the auto focus
is ON.
1)  Set data : 0F to the page : 0, address : 03.
2)  Focus condition can be known from the page A display.
     1 : 00 : XX
Adjustment procedure:
Processing after Adjustments:
Order
Page
Address
Data
Procedure
1
Place a Siemens star at 2m in front of lens.
2
Decrease illumination to the chart down to a point before noise appears on monitor TV,
in order to fully open the IRIS.
3
Shoot the Siemens star at TELE end.
4
Confirm that the image is in focus. (Note).
5
2
21
10
After setting the data, press the PAUSE button.
6
Shoot the Siemens star at WIDE end.
7
Confirm that the image is in focus.
Order
Page
Address
Data
Procedure
1
2
21
00
After setting the data, press the PAUSE button.
2
0
03
00
Set the data. (End)
even : Picture is out of focus.
odd : Picture is in focus.
(
)
Page of 127
Display