CPD-E250 - Sony Monitor Service Manual (repair manual). Page 10

Read Sony CPD-E250 Service Manual online

— 11 —
CPD-E250
SECTION 3: ADJUSTMENTS
  Allow a 30 minute warm-up period prior to making the following 
adjustments.
3-1. LANDING ROUGH ADJUSTMENT
1.  Display the all white pattern.
2.  Adjust the contrast to maximum value.
3.  Display plain green pattern.
4.  Slide the DY back and roughly adjust the plain green pattern with 
the purity magnet so that it is centered on the screen.
5.  Moving the DY forward, adjust so that an entire screen be comes 
pure green.
6.  Adjust the DY tilt and lightly tighten the DY screw.
3-2. LANDING FINE ADJUSTMENT
1.  Place the monitor in the Helmholtz coil.
2.  Set TLH plate to zero position.
3.  Display plain green pattern.
4.  Degauss CRT face and iron parts with degauss equipment or 
hand-degausser. 
5.  Perform auto degauss. 
6.  Attach a wobbling coil to the specifi ed position of CRT neck.
7.  Put the sensor of landing checker to CRT face.
8.   Adjust purity, DY position and DY tilt.
9. Tighten 
DY 
screw.
10.  Perform auto degauss.
11.  Adjust top and bottom pin by pitching DY up and down with two 
wedges so that [a] is equal to [b].
[a]
[b]
12.  If the corner landing is out of specifi cation, use a disk magnet for 
the landing correction.
13.  If disk magnets were used, perform an auto degauss.
Connect the communication cable of the connector located on the D Board on the monitor. Run the service software and then follow the 
instructions.
14.  Remove the wobbling coil and sensor.
15.  Fix the purity magnet on DY with white paint.
3-3. CONVERGENCE ROUGH 
ADJUSTMENT
1.  Enter the white crosshatch signal.
2.  Roughly adjust the horizontal (H.STAT) and vertical (V.STAT) 
convergence at four-pole magnet.
3.  Roughly adjust HMC and VMC at six-pole magnet.
3-4.  CONVERGENCE AND V. KEY (H. TRP) 
FINE ADJUSTMENT
6-pole
Mg
4-pole
Mg
TLH Plate
TB Pin VR
YCV VR
CRT
DY
XCV VR
TLV VR
H-TRP VR
Purity 
Magnet
Neck Ass'y
A Board
1.  Display crosshatch pattern with green lines and black fi eld.
2.  Adjust V. Key (=H. Trapezoid) with H.TRP VR so that [a] is equal 
to [b].
[a]
[b]
3.  Adjust the TB Pin with TB Pin VR.
 
TB Pin Movement
IBM at Computer
as a Jig
1
2
3
1-690-391-21
A-150-919-A
Interface Unit
3-702-691-01
Connector Attachment
To BUS CONNECTOR
D-Sub
(9 Pin [female])
Mini Din
(8 Pin)
4 Pin
4 Pin
4 Pin
* The Parts above (          ) are necessary for DAS Adjustment.
1
3
~
Page of 47
Display

Click on the first or last page to see other CPD-E250 service manuals if exist.