1-3.  A & D BOARD REMOVAL
1
2
4
3
8
5
6
7
— 8 —
CPD-E250
 
Remove (1) screw (+BVTP 3 x 8) from the rear
of the EMI shield.
 
Remove (2) screws (+BVTP 3 x 8) from the sides of  the 
EMI shield.  Lift and remove.
 
Remove (1) screw (+BVTP 3 x 8) from the cable holder 
at the rear of the chassis base to release the cable.
 
Remove (2) screws (+BVTP 3 x 8) from the rear of the 
chassis base and remove.
 
 Remove (2) screws (+BVTP 4 x 16) from the chassis 
base and slide out to remove.
 
Remove (7) screws (+BVTP 3 x 8) from the D Board.  Lift 
the board up and out to remove.
 
Carefully remove the solder connections, and remove 
the shield cover from the A Board
 
Gently wiggle the A Board back and forth, and pull it 
to remove.