CPD-E250 - Sony Monitor Service Manual (repair manual). Page 6

Read Sony CPD-E250 Service Manual online

— 7 —
CPD-E250
1-1. CABINET REMOVAL
SECTION  1: DISASSEMBLY
1
2
3
4
5
 
Remove (2) screws (+BVTP 4 x 16).
 
Release side claw - Insert the tip of a fl athead 
screwdriver approximately 0.25" to unlock the 
claw.
 
Release top claw - Working from the same 
side as the claw in Step 2, insert the tip of a 
fl athead screwdriver to unlock the top claw.
 
Release top claw - Repeat Step 3 on the 
opposite side.
 
Release side claw - Repeat Step 2 on the 
opposite side and gently lift up and then back 
to remove the cabinet.
1.   When the D Board is placed 
in service position, the 
Safety Earth Wire (green 
and yellow wire) is 
disconnected.
2.   After service is completed 
and the D Board reinstalled, 
the Safety Earth Wire must 
be reattached to the chassis 
with the proper screw.  This 
must be confi rmed before 
any subsequent procedures 
are attempted.
1-2. SERVICE POSITION
 
Gently wiggle the A Board back and forth to unplug 
it from the Neck Assembly.
 
Remove all necessary connections and rotate the D 
Board and rest it on its side to expose the bottom.  
Be sure to reconnect all wires.
1
2
3
4
5
1
2
Page of 47
Display