Read Sony DVP-NS648P Service Manual online
6-4
DVP-NS648P
2-2.
Operation of Auto Self Check
When the Self Check mode becomes active at the AC Power ON or by key input, the test display of the following steps (1) to (4) is repeated.
(1) FLD and all ON (for 5 seconds)
(2) MODEL group display (for 2 seconds)
3)
MODEL variation display (for 2 seconds)
a) DVP-NS328/NS628P
b) DVP-NS318
(4) Version display (for 2 seconds)
(2-3. Each Self Check Function
Each Self Check function tests the FLD display, LED display, and key input.
Input
IC404: Pin No. (Signal)
Voltage [V]
PIN
ef (AD1)
PIN
eg (O/C)
PIN
eh (AD2)
PIN
ej (POWER)
0 - 0.20
PLAY
OPEN/CLOSE
STOP
POWER
Click on the first or last page to see other DVP-NS648P service manuals if exist.