SLT-A99, SLT-A99V - Sony Digital Camera Service Manual (repair manual). Page 27

Read Sony SLT-A99 / SLT-A99V Service Manual online

SLT-A99/A99V_L2
2-10
2-1-8. TEBURE UNIT SECTION
ns: not supplied
Ref. No. 
Part No. 
Description
Ref. No. 
Part No. 
Description
351
(Note 5)
359
#76
355
352
(Note 6)
#76
ns
#14
ns
ns
ns
ns
#14
356
(including IC6101 (CMOS imager)
and IS111 board)
(Note 1, 2, 3, 7, 8)
357
358
361
360
ns
353
354
353
354
353
354
#76
ns
ns
362
362
362
362
362
ns
ns
ns
  351 
A-1894-184-A  AS SLIDER UNIT ASSY (SERVICE) (Note 5)
  352 
A-1904-162-A  AS SLIDER B ASSY (SERVICE) (Note 6)
  353 
3-291-553-01 
SCREW, CCD AO ADJUSTMENT
  354 
4-110-892-01 
SPRING, ADJUSTMENT AO
  355 
4-438-938-01 
IM PLATE, OLPF RETAINER (875)
  356 
A-1904-336-A  IMAGER UNIT ASSY 875 (SERVICE)
   
 
(including IC6101 (CMOS imager) and IS111 board) 
   
 
(Note1, 2, 3, 7, 8)
  357 
1-856-450-11 
FILTER BLOCK, OPTICAL (Note 3)
 358 
4-110-938-01  SHEET, 
SPACER
  359 
1-886-243-11 
ISP-008 FLEXIBLE BOARD
  360 
1-886-244-11 
ISL-008 FLEXIBLE BOARD
  361 
4-438-939-01 
IM SHEET GRAPHITE (875)
 362 
2-695-356-11  BALL, 
BEARING
 #14 
2-599-475-11  SCREW 
(M1.7)
 #76 
2-666-551-11  SCREW, 
TAPPING, 
P2
Note
Screw
Note 3:
Precautions for Replacement of Imager
 
If the imager has been replaced, carry out all the adjustments for the 
 
camera section.
 
As the imager may be damaged by static electricity from its structure, 
 
handle it carefully like for the MOS IC.
 
In addition, ensure that the receiver is not covered with dusts nor 
 
exposed to strong light.
Note 3: 
イメージャー交換時の注意
・   イメージャーを交換した場合は,カメラ部の全調整を行ってくださ
い。
・  イメージャーは構造上,静電気により破壊される恐れがあるため,
  MOS ICと同様に注意して取り扱ってください。
  また,受光部にはゴミの付着,および強い光がはいることのない
  ように注意してください。
Note 2:  Refer to “3-2. CLEANING PROCEDURE OF OLPF” on page 
 
3-2 for method of cleaning the OLPF.
Note 7:  Refer to “Assembly-1: Imager Unit Assy”.
Note 2:  OLPFの清掃方法は3-2ページの “3-2. CLEANING PROCEDURE  
OF OLPF” を参照してください。
Note 7:  “Assembly-1: Imager Unit Assy” を参照してください。
Note 4:  Refer to “1-5. METHOD FOR CHECKING THE AS SLIDER 
UNIT (870)” on page 1-3 when checking the AS Slider Unit 
(870).
Note 4:  ASスライダーユニット(870) のチェック行う場合,1-9ペー
ジの “1-5. ASスライダーユニット(870)チェック方法” を参照
してください。
Note 5:  Refer to “1-6. METHOD FOR ADJUSTING THE TEBURE 
REVISE” on page 1-3 when adjusting the Tebure Revise.
Note 6:  Refer to “1-7. METHOD FOR REPLACING THE AS SLIDER 
B ASSY” on page 1-4 when replacing the AS Slider B Assy.
Note 5:  Tebure Reviseの調整を行う場合,1-9ページの  “1-6.  手ぶれ
リバイス調整方法” を参照してください。
Note 6:  ASスライダー B Assyの交換を行う場合,1-10ページの  “1-7. 
ASスライダー B ASSYの交換方法” を参照してください。
#76: M1.7 X 4.0 (Tapping) 
(Silver)
2-666-551-11
4.0
1.7
#14: M1.7 X 2.5 
(Silver)
2-599-475-11
2.5
1.7
The two-layer side is on
the omega unit side.
Mount 
Side
Omega unit
Side
Optical Filter Block
Refer to the following statements when replacing the Optical 
filter block.
Method of Removal
(1)  Pour the solvent (alcohol or liquid cleaner) between the 
omega unit and the spacer sheet.
∗ Please wait until the adhesive strength of the spacer 
sheet gets weaker.
(2)  Detach the spacer sheet from the omega unit.
Method of Attachment
(1)  Attach the Optical filter block to the spacer sheet to make 
the entire area of the optical filter block uniform.
∗ Replace the spacer sheet due to the deformation of
   spacer sheet and the decrease in the adhesive strength 
of the double-faced adhesive tape.
∗ The two-layer side of the optical filter block is on the 
omega unit side.
(2)  Attach the optical filter block and spacer sheet to the 
omega unit so that the entire area of the spacer sheet 
      is uniform.
∗ Be very careful to prevent dust and foreign objects from 
entering during this work.
Pour the solvent (alcohol or liquid cleaner) 
between the omega unit and the spacer sheet.
Spacer Sheet
Omega Unit
Note1:
2層側が
オメガユニット側
マウント
オメガ
ユニット
光学フィルタブロック
Note1: 光学フィルタブロックを交換する際は,下記を参照してくだ
さい。
取り外し方
(1)  オメガユニットと間隔シートの間に溶剤(アルコールま
たはクリーニング液)を流し込む。
間隔シートの粘着力が弱くなるのを待ってください。
(2)  オメガユニットから間隔シート,光学フィルタブロック
を取り外す。
組み付け方
(1)  間隔シートに対し,上下左右が均一になるように
光学フィルタブロックを貼り付ける。
間隔シートは変形、または両面接着力低下するため、
交換してください。
光学フィルタブロックは2層側がイメージャー側に
なります。
(2)  オメガユニットに対し,上下左右が均一になるように
間隔シート,光学フィルタブロックを貼り付ける。
ゴミ侵入には十分注意して作業をお願いします。
オメガユニットと間隔シートの間に溶剤
(アルコールまたはクリーニング液)
を流し込む。
間隔シート
オメガユニット
Note 8: Refer to “1-12. METHOD FOR REPLACING THE IMAGER 
UNIT ASSY” on page 1-7 when replacing the Imager Unit 
Assy.
Note 8:  イメージャー Assyの交換を行う場合,1-14ページの “1-12. イメー
ジャー ASSYの交換方法  を参照してください。
Page of 34